74HC_HCT366_15 Datasheet, PDF (11/21 Pages) NXP Semiconductors – Hex buffer/line driver; 3-state; inverting | |||
|
◁ |
NXP Semiconductors
74HC366; 74HCT366
Hex buffer/line driver; 3-state; inverting
Table 9. Dynamic characteristics 74HCT366
Voltages are referenced to GND (ground = 0 V); CL = 50 pF unless otherwise specified; see test circuit Figure 8.
Symbol Parameter
Conditions
Min Typ Max
Tamb = 25 ï°C
tpd
propagation delay
nA to nY; see Figure 6
[1]
VCC = 4.5 V
-
13 24
ten
enable time
tdis
disable time
tt
transition time
CPD
power dissipation
capacitance
VCC = 5 V; CL = 15 pF
OEn to nY; VCC = 4.5 V; see Figure 7
OEn to nY; VCC = 4.5 V; see Figure 7
VCC = 4.5 V; see Figure 6
per buffer; VI = GND to (VCC ï 1.5 V)
-
[2] -
[3] -
[4] -
[5] -
11 -
16 35
20 35
5
12
30 -
Tamb = ï40 ï°C to +85 ï°C
tpd
propagation delay
ten
enable time
tdis
disable time
tt
transition time
Tamb = ï40 ï°C to +125 ï°C
tpd
propagation delay
ten
enable time
tdis
disable time
tt
transition time
nA to nY; VCC = 4.5 V; see Figure 6
OEn to nY; VCC = 4.5 V; see Figure 7
OEn to nY; VCC = 4.5 V; see Figure 7
VCC = 4.5 V; see Figure 6
nA to nY; VCC = 4.5 V; see Figure 6
OEn to nY; VCC = 4.5 V; see Figure 7
OEn to nY; VCC = 4.5 V; see Figure 7
VCC = 4.5 V; see Figure 6
[1] -
-
30
[2] -
-
44
[3] -
-
44
[4] -
-
15
[1] -
-
36
[2] -
-
53
[3] -
-
53
[4] -
-
18
Unit
ns
ns
ns
ns
ns
pF
ns
ns
ns
ns
ns
ns
ns
ns
[1] tpd is the same as tPHL and tPLH.
[2] ten is the same as tPZH and tPZL.
[3] tdis is the same as tPHZ and tPLZ.
[4] tt is the same as tTHL and tTLH.
[5] CPD is used to determine the dynamic power dissipation (PD in ïW).
PD = CPD ï´ VCC2 ï´ fi ï´ N + ï¥(CL ï´ VCC2 ï´ fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = output load capacitance in pF;
VCC = supply voltage in V;
N = number of inputs switching;
ï¥(CL ï´ VCC2 ï´ fo) = sum of outputs.
74HC_HCT366
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 4 â 4 September 2012
© NXP B.V. 2012. All rights reserved.
11 of 21
|
▷ |