English
Language : 

CAX100 Datasheet, PDF (1/1 Pages) NXP Semiconductors – Plastic Collimator Lens
Philips Competence Centre Plastics B.V.
Optical Components
specification sheet
190 -1
5722 650 3418
page 1/1
1997-12-10 1999-07-13
author: G Verkade
Datasheet Plastic Collimator Lens CAX100
These data concern a full plastic aspherical plano-convex lens. It is specified for use as a collimator in
combination with a diode laser. It can be mounted by use of glue or spring-loaded. Mechanical lock-
mounting is not advisable because of possible distortions.
Parameters
Design conditions
N.A.
Clear Aperture CA
Designed with laser cover glass (BK7) on source side:
Distance from source
Glass thickness
Optical parameters
Focal Length
Back Focal Length BFL (incl BK7-glass)
Free Working Distance FWD
RMS mean
RMS max. (±3σ)
on axis
on axis
Optical Tolerance
Field Radius
Mechanical parameters
Mounting hole diameter Dmh
Other parameters: see drawing
Environmental stability
Storage Temperature
Operating Temperature
Wavelength
670 nm
0.20
4.1
0.55
0.25
10.0
9.21
8.48
35
80
0.1
0.2
∅ 6.28
-25 to 100
-10 to 75
Unit
--
mm
mm
mm
mm
mm
mm
mλ
mλ
mm
mm
mm
°C
°C
General Data:
Transmission [%]: 90
Lens Material: Polycarbonate
Specifications subject to change without notice.
Zemax catalogue file available.