Maximum Ratings
Storage Temperature ................................................................................... -40oC to +125oC
Ambient Temperaturewith Power applied...............................................-20oC to +85oC
SupplyVoltage to Ground Potential(Inputs & VCC Only).......................-0.5Vto+6.0V
SupplyVoltage to Ground Potential(Outputs & D/O Only)...................-0.5Vto+6.0V
DC Input Voltage .............................................................................................-0.5Vto +6.0V
DC Output Current ...................................................................... 20mA
Power Dissipation ......................................................................................................... 500mW
PT8A263
PIR Alarm Controller
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||| |||||||||||||||||||||||||||
Note:
Stresses greater than those listed under MAXIMUM
RATINGS may cause permanent damage to the
device. This is a stress rating only and functional
operation of the device at these or any other condi-
tions above those indicated in the operational sec-
tions of this specification is not implied. Exposure
to absolute maximum rating conditions for extended
periods may affect reliability.
Recommended operation conditions
Sym
Parameter
Min
Typ
Max
Unit
VCC
Supply Voltage
4.75
5.0
6.0
V
VIH
Input HIGH Voltage
0.8 VCC
-
-
V
VIL
Input LOW Voltage
-
-
0.2VCC
V
fSYS
System Oscillator Frequency
12.8
16
19.2
kHz
TA
Operating temperature
-25
-
70
°C
DC Electrical Characteristics
Sym
Description
Test Conditions
Min Typ Max Units
Input high level current - SEL1 and SEL2
-1
-
1
A
IIH
Input high level current - RST
VIH = 4.5V
-1
-
-10
A
Input high level current - OSC
400
-
550
A
Input lowlevel current - SEL1, SEL2, OSC
IIL
Input low level current - OSC
VIL = 0.5V
-1
-
1
A
-10
-
-20
A
IOH
Output Source Current (OUT1, OUT2)
VOH = 4.5V
-6
-12
-
mA
IOL
Output Sink Current (OUT1, OUT2)
VOL = 0.5V
15
55
-
mA
VTH
OSCS Transfer High Voltage
-
2.0
2.3
2.8
V
VTL
OSCS Transfer Low Voltage
-
1.0
1.2
1.6
V
Note: These specifications apply for VCC = 5.0V and -25OC £TA £70OC, unless otherwise specified.
AC Electrical Characteristics
Voltage Regulator
Sym
Description
Test Conditions
VEE
Output Voltage
OP2P Noninverting input of OP2
No load
No load
Vo
Line Regulation
4.5V ≤ VCC ≤ 5.5V, IL = 1mA Cfilter= 4.7uF (between VEE pin and GND pin)
VLDR
IL
Load Regulation
Maximum Current
VCC = 5V, 0.5mA ≤ IL ≤ 2mA Cfilter= 4.7uF (between VEE pinand GND pin)
VCC = 5V
Min Typ Max Units
3.4 3.6 3.8 V
1.6 1.8 2.0 V
- 1.0 50 mV
- 10 100 mV
-4 - - mA
Operational Amplifier and Window Comparator
Sym
Description
UGBW
Unit Gain B and width
VTH
VTL
Windows Comparator Threshold
Test Conditions
-
VCC = 5V
VCC = 5V
Min
Typ
Max
Units
10
-
-
kHz
1.9
2.05
2.2
V
1.4
1.55
1.7
V
12-07-0006
PT0084-6
07/06/12/12