3. Time Counter
Time digit display (in BCD code):
 Second digits: Range from 00 to 59 and carried to minute digits when incremented from 59 to 00.
 Minute digits: Range from 00 to 59 and carried to hour digits when incremented from 59 to 00.
 Hour digits: See description on the /12, 24 bit. Carried to day and day-of-the-week digits when incremented from 11 p.m. to
12 a.m. or 23 to 00.
Addr.
Description
D7
D6
D5
D4
D3
D2
D1
D0
(hex)
02
Seconds
(default)
OSF*1
1
S40
S20
S10
S8
S4
S2
S1
Undefined Undefined Undefined Undefined Undefined Undefined Undefined
03
Minutes
(default)

M40
M20
M10
M8
M4
M2
M1
0
Undefined Undefined Undefined Undefined Undefined Undefined Undefined
04
Hours
(default)


H20
H10
H8
H4
H2
H1
0
0
Undefined Undefined Undefined Undefined Undefined Undefined
*1 Note: Indicate clock integrity. When the bit is 1, the clock integrity is no longer guaranteed and the time need be adjusted.
4. Days of the week Counter
The day counter is a divide-by-7 counter that counts from 00 to 06 and up 06 before starting again from 00. Values that correspond
to the day of week are user defined but must be sequential (i.e., if 0 equals Sunday, then 1 equals Monday, and so on). Illogical
time and date entries result in undefined operation.
Addr.
Description
D7
D6
D5
D4
D3
D2
D1
D0
(hex)
06 Days of the week



(default)
0
0
0


W4
W2
W1
0
0
Undefined Undefined Undefined
5. Calendar Counter
The data format is BCD format.
 Day digits: Range from 1 to 31 (for January, March, May, July, August, October and December).
Range from 1 to 30 (for April, June, September and November).
Range from 1 to 29 (for February in leap years).
Range from 1 to 28 (for February in ordinary years).
Carried to month digits when cycled to 1.
 Month digits: Range from 1 to 12 and carried to year digits when cycled to 1.
 Year digits: Range from 00 to 99 and 00, 04, 08, … , 92 and 96 are counted as leap years.
Addr.
(hex)
05
07
08
Description
Dates
(default)
Months
(default)
Years
(default)
D7
D6
D5
D4
D3
D2
D1
D0


D20
D10
D8
D4
D2
D1
0
0
Undefined Undefined Undefined Undefined Undefined Undefined


Undefined
0

M10
M8
M4
M2
M1
0
Undefined Undefined Undefined Undefined Undefined
Y80
Y40
Y20
Y10
Y8
Y4
Y2
Y1
Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined
2013-06-0002
PT0333-4 06/18/13
10