Si Reverse, low current, 5 – 100MHz, 30.8dB typ. Gain @ 100MHz, 140mA max. @ 24VDC
CHARACTERISTICS
Table 2: Distortion data 5 – 100 MHz; VB = 24V; Tmb = 30°C; ZS = ZL = 75 Ω
SYMBOL PARAMETER
CTB
composite triple beat
XMOD
cross modulation
CSO
d2
STB
composite second order
distortion
second order distortion
third order distortion
CONDITION
7 ch. flat; Vo = 50 dBmV1)
12 ch. flat; Vo = 50 dBmV2)
7 ch. flat; Vo = 50 dBmV1)
12 ch. flat; Vo = 50 dBmV2)
7 ch. flat; Vo = 50 dBmV1)
12 ch. flat; Vo = 50 dBmV2)
3)
4)
MIN.
-
-
-
-
-
-
TYP.
MAX.
- 64
- 61
- 55
- 51
- 68
- 68
- 70
- 66
UNIT
dBc
dBc
dB
dB
dBc
dBc
dBc
dBc
Notes:
1) 7 channels, US frequency raster: T7 – T13 (7.0 to 43.0 MHz), +50 dBmV flat output level.
2) 12 channels, US frequency raster: T7 – T13 (7.0 to 43.0 MHz), 2 – 6 (55.25 to 83.25 MHz),
+50 dBmV flat output level.
3) f1 = 7 MHz; V1 = 50 dBmV; f2 = 25 MHz; V2 = 50 dBmV; fTEST = f1 + f2 = 32 MHz.
4) f1 = 13 MHz; V1 = 50 dBmV; f2 = 25 MHz; V2 = V1; f3 = 7 MHz; V3 = V1;
fTEST = f1 + f2 - f3 = 31 MHz.
Composite Second Order (CSO)
The CSO parameter (both sum and difference products) is defined by the NCTA.
Composite Triple Beat (CTB)
The CTB parameter is defined by the NCTA.
Cross Modulation (XMOD)
Cross modulation (XMOD) is measured at baseband (selective voltmeter method), referenced to 100% modulation of the
carrier being tested.
Page 2 of 4
2004 Nov 01
Document Revision Level A