English
Language : 

S10040280GT Datasheet, PDF (1/4 Pages) PREMIER DEVICES, INC. – GaAs Push Pull Hybrid 40 - 1000MHz 28.0dB min. Gain @ 1000MHz 260mA max. @ 24VDC
Product Specification
S10040280GT
GaAs Push Pull, 40 – 1000MHz, 28.0dB min. Gain @ 1000MHz, 260mA max. @ 24VDC
FEATURES
• Excellent linearity
• Superior return loss performance
• Extremely low distortion
• Optimal reliability
• Low noise
• Unconditionally stable under all terminations
APPLICATION
• 40 to 1000 MHz CATV amplifier systems
DESCRIPTION
• Hybrid Push Pull amplifier module
employing GaAs die
LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 60134)
SYMBOL
Vi
Vov
Tstg
Tmb
PARAMETER
RF input voltage (single tone)
DC supply over-voltage (5 minutes)
storage temperature
operating mounting base temperature
S10040280GT
GaAs Push Pull Hybrid
40 – 1000MHz
28.0dB min. Gain @ 1000MHz
260mA max. @ 24VDC
MIN.
-
-
- 40
- 30
MAX.
75
30
+ 100
+ 100
UNIT
dBmV
V
°C
°C
CHARACTERISTICS
Table 1: S-Parameter, Noise Figure, DC Current; VBB = 24V; Tmb = 30°C; ZS = ZL = 75 Ω
SYMBOL PARAMETER
Gp
power gain
SL
slope 1)
FL
flatness of frequency
response
S11
input return loss
S22
output return loss
F
noise figure
Itot
total current
consumption (DC)
CONDITIONS
f = 45 MHz
f = 1000 MHz
f = 45 to 1000 MHz
f = 45 to 1000 MHz
MIN.
26.7
28.0
1.0
-
TYP.
27.0
28.5
1.5
MAX.
27.3
29.0
2.0
± 0.5
UNIT
dB
dB
dB
dB
f = 40 to 550 MHz 20.0
-
dB
f = 550 to 640 MHz 19.0
-
dB
f = 640 to 1000 MHz 18.0
-
dB
f = 40 to 80 MHz 21.0
-
dB
f = 80 to 160 MHz 19.0
-
dB
f = 160 to 1000 MHz 17.0
-
dB
f = 50 to 1000 MHz -
5.0
dB
250.0 260.0 mA
Notes:
1) The slope is defined as the difference between the gain at the start frequency and the gain at the stop frequency.
Page 1 of 4
2005 Nov 25
Document Revision Level B