English
Language : 

EPC3229G-X_15 Datasheet, PDF (1/1 Pages) PCA ELECTRONICS INC. – High Voltage Flyback Transformer
High Voltage Flyback Transformer
ELECTRONICS INC.
EPC3229G-X
• Used as Flyback Transformer in High Voltage Capacitor Charger
• Designed for use with Linear Technology Chip
• Operating Temperature : -40°C to +85°C
• UL 94V-0 Recognized Components
• UL 1446 Class B Insulation System
• Very Low Core Loss
PCA
Part Number
EPC3229G-1
EPC3229G-2
EPC3229G-3
EPC3229G-4
EPC3229G-5
Primary Peak
Current
(A)
1.4
1.4
1.4
1-2
1-2
Turns
Ratio
Pri:Sec
1:18
1:30
1:20
1:18
1:30
Electrical Parameters @ 25° C
Primary OCL
(µH ± 25%)
@ 0Adc
Leakage
Inductance
(µH Max.)
@ 100 KHz, 0.1 Vrms @ 100 KHz, 0.1 Vrms
12.3
.200
12.3
.200
12.3
.700
7.86
.200
7.86
.200
DCR
(Ω Max.)
Pri.
.300
.300
.300
.300
.300
Sec.
50
75
56
50
75
Isolation
Pri. to Sec.
1200 Vdc or 850 Vrms
1200 Vdc or 850 Vrms
1500 Vrms
1200 Vdc or 850 Vrms
1200 Vdc or 850 Vrms
Schematic
Pri.
Sec.
T1
1
4
V In : 5.0 V
2
3
Package
Pin 1 I.D.
Marking :
PCA
EPC3229G-X
D.C.
.350
(8.90)
1
4
.350
(8.90)
2
3
Recommended
Layout
.422
(10.72)
.277
(7.04)
.205 Max.
(5.20)
PCA ELECTRONICS, INC.
16799 SCHOENBORN ST.
NORTH HILLS, CA 91343
Unless Otherwise Specified Dimensions are in Inches /mm ± .010 /.25
Product performance is limited to specified parameters. Data is subject to change without prior notice.
CSC3229G-X Rev. 2 4/19/05 FT
TEL: (818) 892-0761
FAX: (818) 894-5791