English
Language : 

PE345 Datasheet, PDF (2/4 Pages) Pasternack Enterprises, Inc. – N Male to N Male Right Angle Low Loss Test Cable Using PE-P142LL Coax, RoHS
N Male to N Male Right Angle Low Loss Test
Cable Using PE-P142LL Coax, RoHS
TECHNICAL DATA SHEET
PE345
Frequency 4
Frequency, GHz
Insertion Loss
Power Handling, Watts
Frequency 5
Frequency, GHz
Insertion Loss
Power Handling, Watts
Frequency 6
Frequency, GHz
Insertion Loss
Power Handling, Watts
Frequency 7
Frequency, GHz
Insertion Loss
Power Handling, Watts
Electrical Specification Notes:
3
0.127 dB/ft [0.42 dB/m ]
400
5
0.166 dB/ft [0.54 dB/m ]
300
10
0.24 dB/ft [0.79 dB/m ]
220
18
0.33 dB/ft [1.08 dB/m ]
160
Power handling values are calculated based on Cable
properties. Power handling will vary based on the actual
VSWR of the cable assembly.
Mechanical Specifications
Cable
Cable Type
No of Shields
Dielectric Type
Jacket Material
Cable Color
Jacket Diameter, in [mm]
Connector 1
Type
Configuration
Inner Conductor Material and Plating
Inner Conductor Plating Specification
Outer Conductor Material and Plating
Outer Conductor Plating Specification
Coupling Nut Material and Plating
Coupling Nut Plating Specification
Hex Size, Inch
Torque, in-lbs [Nm]
Dielectric Type
PE-P142LL
3
PTFE
FEP
Green
0.195 [4.95]
N Male
Straight
Beryllium Copper, Gold
ASTM-B488, 50µ Inch.
Passivated Stainless Steel
SAE-AMS-2700
Passivated Stainless Steel
SAE-AMS-2700
3/4
14 [1.58]
PTFE
Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price,
inventory and certifications: N Male to N Male Right Angle Low Loss Test Cable Using PE-P142LL Coax, RoHS PE345
PE345 REV 1.2
2