English
Language : 

PE5SC3004 Datasheet, PDF (1/6 Pages) Pasternack Enterprises, Inc. – 3.5mm Male General Purpose Calibration Kit Component Thru Operating From DC to 8.5 GHz
3.5mm Male General Purpose Calibration Kit
Component Thru Operating From DC to 8.5 GHz
TECHNICAL DATA SHEET
PE5SC3004
Pasternack’s PE5SC3004 offers excellent performance characteristics that is specially designed for the fine-tuning
and calibration of sensitive test equipment in engineering labs, production environments, and quality testing facilities.
All of our calibration kits & components are built to withstand years of rigorous use and provide accurate RF equipment
calibration for the life of the product. Pasternack’s broad portfolio of test and measurement components offer users a
variety of options that are technically and economically suitable for a broad spectrum of RF applications and environments.
As a leading solutions provider of RF calibration instruments and compatible RF components, you can rely on Pasternack to
have all of the T&M products you need in-stock and available to ship same-day.
Features
• Functional from DC to 8.5 GHz
• See PE5CK1001 for full standard kit which includes
(8) 3.5mm short-open-load-thru (SOLT) components
• Suitable for many 50 Ohm network
analyzers including, but not limited to:
• Agilent / HP (8711/8712, 8713/8714, 8753,
E5061A, E5062A, E5061B, E5071C, E5072A)
• Anritsu / Advantest (MS2028S, MS2026S,
MS2025S, MS2024S, MS2038C, MS2036C,
MS2035B, MS2034B, MS4640B, R3755A, R3760)
• Copper Mountain (5048, 804, 304, 818, 814)
• Deviser (NA7300A, NA7100A)
• EI41(AV3656A)
• OuFu (OF7631A, OF7633A)
• PNA (PNA3766, PNA3767)
• Rohde & Schwarz (ZVL, ZVC, ZVB)
• Tianda (TD3616C, TD3617E, TD3618C, TD3619C)
Applications
• VNA, Full 2-Port CAL
• VNA, Thru CAL
• VNA, Substitution CAL Method
• Test & Measurement
• Lab Equipment Accessories
• Engineering Test and Evaluation
• General Purpose Test
and Evaluation
Configuration
Connector
Component Type
Impedance
Frequency Range
Description
Frequency Range
Impedance
Insertion Loss, DC - 8500 MHz
Return Loss, DC - 8500 MHz
3.5mm Male
Thru
50 Ohms
DC to 8.5 GHz
Electrical Specifications
Minimum
30
Typical
DC - 8500
50
0.05
35
Maximum
0.2
Units
MHz
Ohm
dB
dB
Item
Housing
Connector
Connector Screw Thread
Dimensions
Net Weight
Mechanical Specifications
Description
Stainless Steel
50 Ohm 3.5mm Male (Both Ends)
1/4"-36 UNS
0.355 [9] ø, 0.808 [20.5] L
5.5
Units
Inch
Inch [mm]
g