TECHNICAL DATA SHEET
PE360
2.92mm Male to 2.92mm Male Test Cable Using PE-P160 Coax, RoHS
Configuration
Connector 1
Connector 2
Cable Type
Electrical Specifications
Frequency Range, GHz
Impedance, Ohms
Maximum VSWR
Velocity of Propagation, %
RF Shielding, dB
Typical Performance by Frequency
Frequency 1
Frequency, MHz
Insertion Loss
Power Handling, KWatts
Frequency 2
Frequency, MHz
Insertion Loss
Power Handling, KWatts
Frequency 3
Frequency, GHz
Insertion Loss
Power Handling, Watts
Frequency 4
Frequency, GHz
Insertion Loss
Power Handling, Watts
Frequency 5
Frequency, GHz
Insertion Loss
Power Handling, Watts
Frequency 6
Frequency, GHz
Insertion Loss
Power Handling, Watts
2.92mm Male
2.92mm Male
PE-P160
DC to 40
50
1.35:1
78
90
500
0.9 dB/ft [2.95 dB/m ]
1.52
1000
0.13 dB/ft [0.43 dB/m ]
1.07
3
0.23 dB/ft [0.75 dB/m ]
610
6
0.33 dB/ft [1.08 dB/m ]
420
12
0.48 dB/ft [1.57 dB/m ]
290
18
0.61 dB/ft [2 dB/m ]
230