English
Language : 

UF5401G Datasheet, PDF (1/2 Pages) Pan Jit International Inc. – GLASS PASSIVATED JUNCTION ULTRAFAST SWITCHING RCTIFIER
DATA SHEET
UF5401G~UF5407G
GLASS PASSIVATED JUNCTION ULTRAFAST SWITCHING RCTIFIER
VOLTAGE 100 to 800 Volts CURRENT 3.0 Amperes DO-201AD
FEATURES
• Plastic package has Underwriters Laboratory
Flammability Classification 94V-O utilizing
Flame Retardant Epoxy Molding Compound
• Exceeds environmental standards of MIL-S-19500/228.
• Ultra Fast switching for high efficiency.
• Both normal and Pb free product are available :
Normal : 80~95% Sn, 5~20% Pb
Pb free: 98.5% Sn above
Unit: inch(mm)
.052(1.3)
.048(1.2)
MECHANICAL DATA
Case: Molded plastic, DO-201AD
Terminals: Axial leads, solderable per MIL-STD-202,Method 208
Polarity: Band denotes cathode
Mounting Position: Any
Weight: 0.04 ounce, 1.1 gram
.210(5.3)
.188(4.8)
MAXIMUM RATINGSAND ELECTRICAL CHARACTERISTICSFEATURES
Ratings at 25°C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
PARAMETER
Maximum Recurrent Peak Reverse Voltage
SYMBOL UF5401G UF5402G UF5403G UF5404G UF5405G UF5406G UF5407G UNITS
V RRM
100
200
300
400
500
600
800
V
Maximum RMS Voltage
V RMS
70
140
210
280
350
420
560
V
Maximum DC Blocking Voltage
VDC
100
200
300
400
500
600
800
V
Maximum Average Forward Current .375"(9.5mm)
lead length at TA=55OC
IAV
3.0
A
Peak Forward Surge Current : 8.3ms single half sine-
wave superimposed on rated load(JEDEC method)
IF S M
150
A
Maximum Forward Voltage at 3.0A
VF
1.0
1.3
1.5
1.7
V
Maximum DC Reverse Current TJ =25OC
at Rated DC Blocking Voltage TJ =100OC
IR
10.0
300
uA
Typi cal Juncti on capaci tance (Note 1)
CJ
75
pF
Typi cal Thermal Resi stance(Note 2)
RθJA
60
OC / W
Maxi mum Reverse Recovery Ti me (Note 3)
TRR
50
75
ns
Operati ng Juncti on and S torage Temperature Range
TJ,TSTG
-55 TO +150
OC
NOTES:
1. Measured at 1 MHz and applied reverse voltage of 4.0 VDC.
2. Thermal Resistance from Junction to Ambient and from Junction to lead length 0.375”(9.5mm) P.C.B. mounted.
3. Test Condition: Ta = Tj Per pulse test pulse width 300uS duty ≤ 2%
STAD-SEP.01.2004
PAGE . 1