PQ Datasheet, PDF (2/3 Pages) Panasonic Battery Group – 1a 5A small size power relay for interface
PQ
RATING
1. Coil data
Nominal coil
voltage
3V DC
5V DC
6V DC
9V DC
12V DC
18V DC
24V DC
Pick-up voltage
(at 20°C 68°F)
75%V or less of
nominal voltage
(Initial)
Drop-out voltage
(at 20°C 68°F)
5%V or more of
nominal voltage
(Initial)
Nominal operating
current
[±10%] (at 20°C 68°F)
66.7mA
40mA
33.3mA
22.2mA
16.7mA
11.1mA
8.3mA
Coil resistance
[±10%] (at 20°C 68°F)
45Ω
125Ω
180Ω
405Ω
720Ω
1,620Ω
2,880Ω
Nominal operating
power
200mW
Max. applied voltage
180%V of
nominal voltage
(at 20°C 68°F)
130%V of
nominal voltage
(at 70°C 158°F)
2. Specifications
Characteristics
Item
Specifications
Contact
Arrangement
Contact resistance (Initial)
Contact material
1 Form A (Bifurcated)
Max. 50 mΩ (By voltage drop 6 V DC 1A)
Au-clad AgNi type
Nominal switching capacity (resistive load)
5 A 250 V AC, 5 A 30 V DC
Max. switching power (resistive load)
1,250 VA, 150 W
Rating
Max. switching voltage
Max. switching current
250 V AC, 110 V DC (0.3 A)
5A
Nominal operating power
Min. switching capacity (Reference value)*1
Insulation resistance (Initial)
Breakdown voltage Between open contacts
(Initial)
Between contact and coil
200 mW
100µA 100mV DC
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA.)
4,000 Vrms for 1min. (Detection current: 10mA.)
Electrical
characteristics
Surge breakdown
voltage (Initial)*2
Between contacts and coil
Temperature rise (coil)
Operate time (at 20°C 68°F) (Initial)
8,000 V
Max. 45°C (By resistive method, nominal coil voltage applied to the coil, contact carrying
current: 5 A, at 70°C)
Max. 20 ms (Nominal voltage applied to the coil, excluding contact bounce time.)
Mechanical
characteristics
Expected life
Conditions
Release time (at 20°C 68°F) (Initial)
Shock resistance
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Electrical (at 20 times/min.)
Conditions for operation, transport and storage*3
Max. operating speed (at rated load)
Max. 10 ms (Nominal voltage applied to the coil, excluding contact bounce time.)
(without diode)
294 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 2.0 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 3.5 mm
Min. 2×107 (at 180 times/min.)
Min. 2×105 (5 A 125 V AC), Min. 105 (5 A 250 V AC), Min. 105 (5 A 30 V DC)
Ambient temperature: –40°C to 70°C –40°F to 158°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min.
Unit weight
Approx. 7 g .25 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
1. Max. switching capacity
100
AC resistive load
10
5
1
DC resistive load
0.3
10 30 100 250 1,000
Contact voltage, V
2. Operate & release time
Tested sample: PQ1a-24V, 25 pcs.
8
6
4
2
0 80
Operate time
Release time
Max.
Min.
Max.
Min.
100
120
150
Coil applied voltage, %V
3. Coil temperature rise
Measured portion: Inside the coil
Contact carrying current: 5 A
70
60
50
50°C
40
30
20
70°C
10
0 100 110 120 130 140 150 160
Coil applied voltage,%V
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
ASCTB206E 201202-T