English
Language : 

HE-V Datasheet, PDF (2/5 Pages) Panasonic Battery Group – HE-V RELAYS
HE-V
RATING
1. Coil data
Nominal coil
voltage
6V DC
9V DC
12V DC
15V DC
24V DC
Pick-up voltage
(at 20°C 68°F)
(Initial)
70%V or less of
nominal voltage
Drop-out voltage
(at 20°C 68°F)
(Initial)
5%V or more of
nominal voltage
Nominal operating
current
[±10%] (at 20°C 68°F)
320mA
213mA
160mA
128mA
80mA
Coil resistance
[±10%] (at 20°C 68°F)
18.8Ω
42.2Ω
75.0Ω
117.0Ω
300.0Ω
Nominal operating
power
1,920mW
Max. applied voltage
(at 55°C 131°F)
110%V of
nominal voltage
2. Specifications
Characteristics
Item
Specifications
Arrangement
2 Form A
Contact
Contact material
Contact resistance (Initial)
Contact rating (Resistive load)
AgNi type
Max. 100 mΩ (By voltage drop 6 V DC 1 A),
Max. 3 mΩ (By voltage drop 6 V DC 20 A, Reference value)
20 A 800 VDC (at each 1 Form A contact connected in series),
20 A 400 VDC (at 1 Form A contact only)
Rating
Max. switching voltage
Max. switching current
1,000 V DC
20 A
Min. switching capacity (Reference value)*1
Insulation resistance (Initial)
100 mA 5 V DC
Min. 1,000MΩ (at 1,000V DC) Measurement at same location as “Breakdown voltage” section.
Short current (Initial)
Max. 300 A 1 ms (Reference value)
Breakdown
voltage (Initial)
Between open contacts
Between contact sets
Between contact and coil
2,000 Vrms for 1 min. (Detection current: 10 mA)
4,000 Vrms for 1 min. (Detection current: 10 mA)
5,000 Vrms for 1 min. (Detection current: 10 mA)
Electrical
characteristics
Mechanical
characteristics
Surge breakdown voltage*2
(Between contact and coil) (Initial)
Coil temperature rise value
Coil holding voltage*3
Operate time (at 20°C 68°F)
Release time (at 20°C 68°F)
Shock
resistance
Functional
Destructive
Vibration
resistance
Functional
Destructive
Min. 10,000 V
Max. 75°C 135°F (By resistive method, contact carrying current: 20A,
100%V of nominal coil voltage at 55°C 131°F.)
Max. 45°C 113°F (By resistive method, contact carrying current: 20A,
60%V of nominal coil voltage at 85°C 185°F.)
33 to 110%V (Contact carrying current: 20A, at 55°C 131°F),
33 to 60%V (Contact carrying current: 20A, at 85°C 185°F)
Max. 30 ms (nominal coil voltage, without bounce)
Max. 10 ms (nominal coil voltage) (without diode)
Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10 µs)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms)
10 to 55 Hz at double amplitude of 1.0 mm (Detection time: 10 µs)
10 to 55 Hz at double amplitude of 1.5 mm
Expected life
Mechanical life
Min. 106 (at 180 cpm)
Conditions
Conditions for operation, transport and
storage*4
Ambient temperature:
–40 to +55°C –40 to +131°F (When coil holding voltage is 33% to 110% of nominal coil voltage)
–40 to +85°C –40 to +185°F (When applied coil hold voltage is 33% to 60% of nominal coil voltage)
Humidity: 5 to 85% R.H. (Not freezing and condensing)
Max. operating speed
6 times/min. (at nominal switching capacity ON : OFF = 1s : 9s)
Unit weight
Approx. 120 g 4.23 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. Coil holding voltage is the coil voltage after 100 ms following application of the nominal coil voltage.
*4. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
ASCTB326E 201212-T