English
Language : 

DE Datasheet, PDF (2/4 Pages) Panasonic Battery Group – DE RELAYS
DE (ADE)
RATING
1. Coil data
1) Single side stable type
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
5V DC
12V DC
24V DC
70%V or less of
nominal voltage
(Initial)
Drop-out voltage
(at 20°C 68°F)
10%V or more of
nominal voltage
(Initial)
Nominal operating
current
[±10%] (at 20°C 68°F)
40 mA
16.6mA
8.3mA
Coil resistance
[±10%] (at 20°C 68°F)
125Ω
720Ω
2,880Ω
Nominal operating
power
200mW
Max. applied voltage
(at 20°C 68°F)
130%V of
nominal voltage
2) 2 coil latching type
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
5V DC
12V DC
24V DC
70%V or less of
nominal voltage
(Initial)
Reset voltage
(at 20°C 68°F)
70%V or less of
nominal voltage
(Initial)
Nominal operating
current
[±10%] (at 20°C 68°F)
Set coil Reset coil
40 mA 40 mA
16.6mA 16.6mA
8.3mA
8.3mA
Coil resistance
[±10%] (at 20°C 68°F)
Set coil
125Ω
720Ω
2,880Ω
Reset coil
125Ω
720Ω
2,880Ω
Nominal operating
power
Set coil Reset coil
200mW 200mW
Max. applied voltage
(at 20°C 68°F)
130%V of
nominal voltage
2. Specifications
Characteristics
Contact
Rating
Electrical
characteristics
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity*1
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Between open contacts
Between contact sets
Between contact and coil
Surge breakdown voltage*2
(Between contact and coil) (Initial)
Temperature rise (coil) (at 70°C 158°F)
Operate time [Set time] (at 20°C 68°F)
Mechanical
characteristics
Release time [Reset time] (at 20°C 68°F)
Shock resistance
Vibration resistance
Mechanical
Functional
Destructive
Functional
Destructive
Expected life
Electrical
Conditions
Unit weight
Conditions for operation, transport and storage*3
Max. operating speed
Specifications
1 Form A
1 Form A 1 Form B
2 Form A
Max. 30 mΩ (By voltage drop 6 V DC 1A)
AgSnO2 type
10A 250V AC, 10A 30V DC
8A 250V AC, 8A 30V DC
2,500VA, 300W
2,000VA, 240W
250V AC, 30V DC
250V AC, 30V DC
10A
8A
200mW
100mA 5V DC
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1 min. (Detection current: 10 mA)
—
4,000 Vrms for 1 min. (Detection current: 10 mA)
5,000 Vrms for 1 min. (Detection current: 10 mA)
12,000 V
Max. 50°C 122°F (By resistive method)
Max. 10 ms [Max. 10 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 5 ms [Max. 10 ms]
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 2 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 3 mm
Min. 107 (at 300 times/min.)
Min. 105
(resistive load, at 20 times/min., at nominal switching capacity)
Min. 105 (resistive load,
at 20 times/min., at AC nominal
switching capacity)
Min. 5×104 (resistive load,
at 20 times/min., at DC nominal
switching capacity)
Ambient temperature: –40°C to +70°C –40°F to +158°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at nominal switching capacity)
Approx. 7 g .25 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
ASCTB175E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/