English
Language : 

HHR75AAA Datasheet, PDF (1/1 Pages) Panasonic Battery Group – NICKEL METAL HYDRIDE BATTERIES
NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET
HHR75AAA/B Cylindrical AAA size (HR 11/45)
Dimensions (with Tube)
(mm)
10.5
+-
0
0.7
(+)
Typical Charge Characteristics
2.0
1.9
Charge: 450mA (0.64 It) x 1.7hrs
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0˚C
20˚C
45˚C
0 10 20 30 40 50 60 70 80 90 100 110 120
Charge Time (minutes)
44.5
+-
0
1.0
Typical Discharge Characteristics
()
Specifications
Diameter
Height
Approximate
Weight
mm
10.5+0/-0.7
44.5+0/-1.0
Grams
12
inch
0.41+0/-0.03
1.75+0/-0.04
Ounces
0.42
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0
Charge: 450mA (0.64It) x 1.7 hrs, 20˚C.
Discharge Temperature: 20˚C.
140mA
(0.2It)
1
2
3
4
5
6
Discharge Time (hours)
Nominal Voltage
1.2V
Discharge
Capacity*
Average**
Rated (Min.)
730 mAh
700 mAh
Approx. Internal impedance
at 1000Hz at charged state.
35mΩ
Charge
Standard
Rapid
70mA x 16hrs.
450mA x 1.7 hrs.
Charge Standard
Rapid
Discharge
˚C
0˚C to 45˚C
0˚C to 40˚C
-10˚C to 65˚C
˚F
32˚F to 113˚F
32˚F to 104˚F
14˚F to 149˚F
Storage
< 1 year
< 3 months
< 1 month
-20˚C to 35˚C
-20˚C to 45˚C
-20˚C to 55˚C
-4˚F to 95˚F
-4˚F to 113˚F
-4˚F to 131˚F
* After charging at 0.1It for 16 hours, discharging at 0.2It.
** For reference only.
Battery performance and cycle life are strongly affected by how they
are used. In order to maximize battery safety, please consult Panasonic
when determining charge / discharge specs, warning label contents
and unit design.
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0
Charge: 450mA (0.64It) x 1.7hrs, 20˚C.
Discharge Temperature: 20˚C.
700mA (1It)
1400mA (2It)
10
20
30
40
50
60
70
80
Discharge Time (hours)
Note:
[It] was previously expressed as [C]. [It] is an IEC standard expression
for the amount of charge or discharge current and is expressed as:
It(A) = Cn (Ah)/1h.
• [It] is the reference test current in ampres
• [Cn] is the rated capacity of the cell or battery in Ampere-hours.
n = the time base [hours] for which the rated capacity is declared
NICKEL METAL HYDRIDE HANDBOOK
AUGUST 2005
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to
modification without notice. Contact Panasonic for the latest information.