English
Language : 

HHR300CH Datasheet, PDF (1/1 Pages) Panasonic Battery Group – NICKEL METAL HYDRIDE BATTERIES:
NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET
HHR300CH Cylindrical C size (HR 26/50) for backup use
Dimensions (with Tube)
(mm)
25.8
+-
0
1.0
(+)
Typical Charge Characteristics
2.0
Charge: 300mA(0.1 It) x 16hrs.
1.8
1.6
1.4
1.2
1.0
10˚C
25˚C
60˚C
0.8
0 2 4 6 8 10 20 30 40 50 60
Charge Time (hours)
50.0
+-
0
1.5
Specifications
Diameter
Height
Approximate
Weight
()
mm
25.8+0/-1.0
50.0+0/-1.5
Grams
80
inch
1.02+0/-0.04
1.97+0/-0.06
Ounces
2.82
Nominal Voltage
1.2V
Discharge
Capacity1
Average2
Rated (Min.)
3300 mAh
3100 mAh
Approx. Internal impedance
at 1000Hz at charged state.
5mΩ
Charge
Standard
Rapid3
300mA (0.1It) x 16hrs.
1500mA (1It) x 2.4 hrs.4
Low Rate
Standard
Charge
Rapid
Low Rate
Discharge
155mA x 32 hrs.
100mA x 48 hrs.
˚C
˚F
0˚C to 45˚C 32˚F to 113˚F
10˚C to 40˚C 32˚F to 104˚F
-10˚C to 45˚C 14˚F to 149˚F
-10˚C to 65˚C 14˚F to 113˚F
Storage
< 1 year
< 3 months
< 1 month
-20˚C to 35˚C
-20˚C to 35˚C
-20˚C to 55˚C
-4˚F to 95˚F
-4˚F to 95˚F
-4˚F to 131˚F
1 After charging at 0.1It for 16 hours, discharging at 0.2It.
2 For reference only.
3 Need specially designed control system
Control System:
dT/dt cut-off; 1 to 2°C/min
-UV cut-off; -UV per cell = 5 to 10 mV
T-control; T=65°C
Rapid charger timer; 2.4h (at 1.25a)
Trickle timer; within 2h
4 With control system
Battery performance and cycle life are strongly affected by how they are used. In
order to maximize battery safety, please consult Panasonic when determining
charge / discharge specs, warning label contents and unit design.
Typical Discharge Characteristics
120
110
100
90
80
70
60
Charge: 300mA (0.1 It) x 16 hrs.
Charge Temperature: -10 to 60˚C
50
Discharge: 600mA (0.2 It)
40
Cut-off Voltage: 1.0V
Discharge Temperature: 25˚C
30
-20 -10 0 10 20 30 40 50 60 70
Temperature (°C)
1.8
Charge: 300mA(0.1It) x 16 hrs., 25°C
Discharge: 10A, 20A, 25°C
1.6
1.4
1.2
1.0
10A
20A
0.8
0
5
10
15
20
25
30
Discharge Time (minutes)
Note:
[It] was previously expressed as [C]. [It] is an IEC standard expression
for the amount of charge or discharge current and is expressed as:
It(A) = Cn (Ah)/1h.
• [It] is the reference test current in ampres
• [Cn] is the rated capacity of the cell or battery in Ampere-hours.
n = the time base [hours] for which the rated capacity is declared
NICKEL METAL HYDRIDE HANDBOOK
AUGUST 2005
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to