English
Language : 

HHR250SCH Datasheet, PDF (1/1 Pages) Panasonic Battery Group – NICKEL METAL HYDRIDE BATTERIES:
NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET
HHR250SCH Cylindrical SC size (HR 23/43)
Dimensions (with Tube)
(mm)
23.0
+-
0
1.0
(+)
43.0
+-
0
1.5
Typical Charge Characteristics
2.0
Charge: 0.1It x 15h at 25, 40, 60˚C Rest: 3h
Discharge: 0.1It to 1.0V at 25˚C
1.8
1.6
1.4
1.2
1.0
0.8
0
25˚C
40˚C
60˚C
500 1000 1500 2000 2500 3000 3500 4000 4500
Capacity (mAh)
Typical Discharge Characteristics
()
Specifications
Diameter
Height
Approximate
Weight
mm
23.0+0/-1.0
43.0+0/-1.5
Grams
55
inch
0.91+0/-0.04
1.69+0/-0.06
Ounces
1.94
Nominal Voltage
Discharge
Average2
Capacity1
Rated (Min.)
Approx. Internal impedance
at 1000Hz at charged state.
Standard
Charge
Rapid3
Low Rate
Charge
Standard
Rapid
Discharge
< 1 year
Storage
< 6 months
< 1 month
< 1 week
1.2V
2650 mAh
2500 mAh
5mΩ
250mA x 16hrs.
1250mA x 2.4 hrs.4
125mA x 32 hrs.
83mA x 48 hrs.
˚C
˚F
-10˚C to 60˚C 14˚F to 140˚F
-10˚C to 45˚C 14˚F to 113˚F
-10˚C to 60˚C 14˚F to 140˚F
-20˚C to 35˚C -4˚F to 95˚F
-20˚C to 45˚C -4˚F to 113˚F
-20˚C to 55˚C -4˚F to 131˚F
-20˚C to 65˚C -4˚F to 149˚F
1 After charging at 0.1It for 16 hours, discharging at 0.2It.
2 For reference only.
3 Need specially designed control system
Control System:
dT/dt cut-off; 1 to 2°C/min
-UV cut-off; -UV per cell = 5 to 10 mV
T-control; T=65°C
Rapid charger timer; 2.4h (at 1.25a)
Trickle timer; within 2h
4 With control system
Battery performance and cycle life are strongly affected by how they
are used. In order to maximize battery safety, please consult Panasonic
when determining charge / discharge specs, warning label contents
and unit design.
2.0
Charge: 0.5It x 2.4h at 25˚C Rest: 1h
Discharge: 1, 2, 3It to 0.8V at 25˚C
1.8
1.6
1.4
1.2
1.0
0.8
0
1It
2It
3It
500 1000 1500 2000 2500 3000 3500 4000 4500
Capacity (mAh)
1.6
Charge: 0.5It x 2.4h Rest: 1h
1.5
Discharge: 10, 20, 30A to 0.8V at 20˚C
1.4
1.3
1.2
10A
1.1
20A
1.0
30A
0.9
0.8
0.7
0.6
0
500
1000 1500 2000 2500 3000
Capacity (mAh)
Note:
[It] was previously expressed as [C]. [It] is an IEC standard expression
for the amount of charge or discharge current and is expressed as:
It(A) = Cn (Ah)/1h
* [It] is the reference test current in ampres
* [Cn] is the rated capacity of the cell or battery in Ampere-hours.
n = the time base [hours] for which the rated capacity is declared
NICKEL METAL HYDRIDE HANDBOOK
AUGUST 2005
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to