English
Language : 

ERT-J1VS104FA Datasheet, PDF (7/14 Pages) Panasonic Semiconductor – The NTC Thermistors
Multilayer NTC Thermistors
■ Part Number List of Standard Type (Resistance Tolerance : ±5 %, ±3 %)
● 0201(EIA)
Nominal
Resistance
at 25 °C
Resistance
Tolerance
B value class code
Nominal B value B25/50
✽() Reference value B25/85
G
(3375 K)
3435 K±2 %
P
4050 K±3 %
(4100 K)
2.0 kΩ
3.0 kΩ
4.7 kΩ
10 kΩ
47 kΩ
±3 %(H)
or
±5 %(J)
ERTJZEG103□A
ERTJZEP473□
100 kΩ
□ : Resistance Tolerance Code
Avoid flow soldering.
T
4500 K±2 %
(4450 K)
ERTJZET202□
ERTJZET302□
ERTJZET472□
● 0402(EIA)
Nominal
Resistance
at 25 °C
Resistance
Tolerance
B value class code
Nominal B value B25/50
✽() Reference value B25/85
22 Ω
33 Ω
40 Ω
47 Ω
68 Ω
±3 %(H)
or
±5 %(J)
100 Ω
150 Ω
A
2750 K±3 %
(2700 K)
2800 K±3 %
(2750 K)
ERTJ0EA220□
ERTJ0EA330□
ERTJ0EA400□
ERTJ0EA470□
ERTJ0EA680□
ERTJ0EA101□
ERTJ0EA151□
V
4700 K±2 %
(4750 K)
ERTJZEV104□
Nominal
Resistance
at 25 °C
Resistance
Tolerance
B value class code
Nominal B value B25/50
✽() Reference value B25/85
3.3 kΩ
4.7 kΩ
6.8 kΩ
10 kΩ
15 kΩ
22 kΩ
±3 %(H)
or
±5 %(J)
33 kΩ
47 kΩ
100 kΩ
G
(3375 K)
3435 K±1 %
ERTJ0EG103□A
M
3900 K±2 %
(3970 K)
ERTJ0EM103□
P
4050 K±2 %
(4100 K)
ERTJ0EP333□
ERTJ0EP473□
ERTJ0EP104□
R
4250 K±2 %
(4300 K)
ERTJ0ER332□
ERTJ0ER472□
ERTJ0ER682□
ERTJ0ER103□
ERTJ0ER153□
ERTJ0ER223□
ERTJ0ER333□
Nominal
Resistance
at 25 °C
Resistance
Tolerance
B value class code
Nominal B value B25/50
✽() Reference value B25/85
1.0 kΩ
1.5 kΩ
2.0 kΩ
2.2 kΩ
3.0 kΩ
3.3 kΩ
4.7 kΩ
47 kΩ
68 kΩ
100 kΩ
150 kΩ
220 kΩ
330 kΩ
470 kΩ
±3 %(H)
or
±5 %(J)
□ : Resistance Tolerance Code
Avoid flow soldering.
S
4330 K±2 %
(4390 K)
ERTJ0ES104□
T
4500 K±2 %
(4450 K, 4580 K)
ERTJ0ET102□
ERTJ0ET152□
ERTJ0ET202□
ERTJ0ET222□
ERTJ0ET302□
ERTJ0ET332□
ERTJ0ET472□
ERTJ0ET104□
ERTJ0ET154□
V
4700 K±2 %
(4750 K)
ERTJ0EV473□
ERTJ0EV683□
ERTJ0EV104□
ERTJ0EV154□
ERTJ0EV224□
ERTJ0EV334□
ERTJ0EV474□
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Dec. 2013