English
Language : 

PM4HS-H-AC240V Datasheet, PDF (6/24 Pages) Panasonic Semiconductor – MULTI-RANGE ANALOG TIMER
PM4H-A/S/M
Time range
Scale
1
5
10
50
Time unit
Control
time range
sec
0.1s to 1s
0.5s to 5s
1.0s to 10s
5s to 50s
min
0.1 min to 1 min
0.5 min to 5 min
1.0 min to 10 min
5 min to 50 min
Note: 0 setting is for instantaneous output operation.
hrs
0.1h to 1h
0.5h to 5h
1.0h to 10h
5h to 50h
10h
1.0h to 10h
5h to 50h
10h to 100h
50h to 500h
PM4H-A/PM4H-S/PM4H-M
All types of PM4H timer have multi-time
range.
16 time ranges are selectable.
1s to 500h (Max. range) is controlled.
Specifications
Item
Rating
Rated operating voltage
Rated frequency
Type
Rated power consumption
Rated control capacity
Operating mode
Time
accuracy
Note:)
Time range
Operating time fluctuation
Setting error
Voltage error
Temperature error
Contact
Life
Contact arrangement
Contact resistance (Initial value)
Contact material
Mechanical (contact)
Electrical (contact)
Allowable operating voltage range
Electrical
function
Insulation resistance (Initial value)
Breakdown voltage (Initial value)
Mechanical
function
Operating
condition
Others
Min. power off time
Max. temperature rise
Functional
Vibration resistance
Destructive
Shock resistance
Functional
Destructive
Ambient temperature
Ambient humidity
Atmospheric pressure
Ripple factor (DC type)
Protective construction
Weight
PM4H-A
PM4H-S
PM4H-M
100 to 240V AC, 48 to 125V DC, 12V DC, 24V AC/DC
50/60Hz common (AC operating type)
Approx. 10VA (100 to 240V AC)
Approx. 2.5VA (24V AC)
Approx. 1.5W (12V DC, 24V DC, 48 to 125V DC)
5A 250V AC (resistive load)
Pulse ON-delay
Pulse Flicker
Pulse ON-Flicker
Differential ON/OFF-delay (1) (2)
Signal OFF-delay
Pulse One-shot
Pulse One-cycle
Power ON-delay
Power ON-delay
Power Flicker
Power ON-flicker
Power One-shot
Power One-cycle
(with instantaneous contact)
1s to 500h (Max.) 16 time ranges switchable
±0.3% (power off time change at the range of 0.1s to 1h)
±5% (Full-scale value)
±0.5% (at the operating voltage changes between 85 to 110%)
±2% (at 20°C ambient temp. at the range of –10 to +50°C +14 to +122°F)
Timed-out 2 Form C
Timed-out 1 Form C
Instantaneous 1 Form C
Max. 100mΩ (at 1A 6V DC)
Silver alloy
Au flash on Silver alloy
2×107
105 (at rated control capacity)
85 to 110% of rated operating voltage (at 20°C coil temp.)
Min. 100MΩ
Between live and dead metal parts
Between input and output
Between contacts of different poles
Between contacts of same pole
(At 500V DC)
2,000Vrms for 1 min Between live and dead metal parts
2,000Vrms for 1 min Between input and output
2,000Vrms for 1 min Between contacts of different poles
1,000Vrms for 1 min Between contacts of same pole
100ms
55°C 131°F
65°C 149°F
10 to 55Hz: 1 cycle/min double amplitude of 0.25mm (10min on 3 axes)
10 to 55Hz: 1 cycle/min double amplitude of 0.375mm (1h on 3 axes)
Min. 98m/s2 (4 times on 3 axes)
Min. 980m/s2 (5 times on 3 axes)
–10 to +50°C +14 to +122°F
30 to 85%RH (at 20°C 68°F, non-condensing)
860 to 1,060hPa
20%
IP65 on front panel (using rubber gasket ATC18002) <only for IP65 type>
100g 3.527 oz (Pin type)
110g 3.880 oz (Screw terminal type)
Note: 1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within 5% ripple
factor for DC), 20°C 68°F ambient temperature, and 1s power off time.
2) For the 1s range, the tolerance for each specification becomes ±10ms.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.