ERZC20EK201Y Datasheet, PDF (6/6 Pages) Panasonic Semiconductor – ZNR Transient/Surge Absorbers
“ZNR” Transient/Surge Absorbers (Type E)
Performance Characteristicsv (Type E)
Characteristics
Test Methods/Description
Specifications
Standard Test
Condition
Electrical characteristics shall be measured at following conditions
(Temperature: 5 to 35 °C,Humidity: Max. 85 %)
———
Varistor Voltage
The voltage between two terminals with the specified measuring
current CmA DC applied is called Vc or VCmA. The measurement shall
be made as fast as possible to avoid heat affection.
Maximum Allowable The maximum sinusoidal wave voltage (rms) or the maximum DC
Voltage
voltage that can be applied continuously.
Clamping Voltage
The maximum voltage between two terminals with the specified
standard impulse current (8/20 μs).
Rated Power
The maximum power that can be applied within the specified To meet the
ambient temperature.
specified value.
Energy
The maximum energy within the varistor voltage change of ±10 %
when one impulse of 2 ms is applied.
The maximum current within the varistor voltage change of ±10 %
2 times with the standard impulse current (8/20 μs) applied two times with
Maximum
an interval of 5 minutes.
Peak Current
1 time
The maximum current within the varistor voltage change of ±10 %
with the standard impulse current (8/20 μs) applied one time.
Temperature Coefficient
of Varistor Voltage
VC at 70 °C – VC at 20 °C
VC at 20 °C
×
1
50
×
100 (%/°C)
0 to –0.05 %/°C max.
Impulse Life
The change of Vc shall be measured after the impulse listed
below is applied 10000 times continuously with the interval of ten
seconds at room temperature.
20 Series
32 Series
200 A (8/20 μs)
300 A (8/20 μs)
ΔV1 mA/V1 mA < ±10 %
Withstanding Voltage The commercial frequency voltage of AC 2.5 kV shall be applied No remarkable
(Body Insulation)
between terminals and the bottom of the unit for one minute.
damage
Robustness of
Terminations
(Tensile)
Vibration
After gradually applying the load of 49 N (5 kgf) and keeping the
unit fixed for 10 seconds in an axial direction, the terminal shall
be visually examined for any damage.
After repeadly applying a single harmonic vibration (amplitude:
0.75 mm): double amplitude: 1.5 mm with 1 minute vibration
frequency cycles (10 Hz to 55 Hz to 10 Hz) to each of three
perpendicular directions for 2 hours. Thereafter, the damage of
the terminals is visually examined.
No remarkable
damage
Dry Heat/ High
Temperature
Storage
The specimen shall be subjected to 110±3 °C for 500 hours
in a thermostatic bath without load and then stored at room
temperature and humidity for one to two hours. Thereafter, the
change of Vc shall be measured.
Step
1
2
3
4
Temperature (°C)
–25
–
0
3
Room Temp.
85+30
Room Temp.
Period (minutes)
30+30
3 max.
30+30
3 max.
ΔV1 mA/V1 mA < ±5 %
Temperature Cycle
The temperature cycle shown below shall be repeated five
times and then stored at room temperature and humidity for
one to two hours. The change of Vc and mechanical damage
shall be examined.
No remarkable
damage
ΔV1 mA/V1 mA < ±5 %
Dry Heat Load/
High Temperature
Load
After being continuously applied the Maximum Allowable Voltage
at 85±5 °C for 500 hours, the specimen shall be stored at room
temperature and humidity for one to two hours. Thereafter, the
ΔV1 mA/V1 mA < ±10 %
change of Vc shall be measured.
The specimen shall be subjected to 40±2 °C, 90 to 95 %RH for
Damp Heat/Humidity
(Steady State)
1000 hours without load and then stored at room temperature
and humidity for one to two hours. Thereafter, the change of Vc
ΔV1 mA/V1 mA < ±5 %
shall be measured.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
03 Mar. 2017