English
Language : 

EYP-2BN126 Datasheet, PDF (4/8 Pages) Panasonic Semiconductor – Thermal Cutoffs (TCO)
Thermal Cutoffs (TCO)
● ML series
Part No.
Type No. of
Approved
Standards
Rated
Functioning
Temp.✽1
(°C)
Functioning
Temp.✽2
(°C)
Maximum
Operating
Temp.✽3
(°C)
Holding
Temp.✽4
(°C)
Maximum
Temp.
Limit
(°C)✽5
AC/
DC
Electrical
Rating
Amp.
(A)
Volt.
(V)
Approved Safety
Standards
UL
VDE CCC
RoHS
EYP2ML092
ML092
92
89±2
55
60
135
DC
2
50
ć
ć
ć
EYP2ML092U
—
92
89+–43
55
60
135
DC
2
50
Under
Under
Under
Application Application Application
EYP2ML098
ML098
98
94±2
60
65
135
DC
2
50
ć
ć
ć
EYP2ML098U
—
98
94+–23.5
60
65
135
DC
2
50
Under
Under
Under
Application Application Application
EYP2ML102
ML102
102
98±2
65
70
135
DC
2
50
ć
ć
ć
EYP2ML102U
—
102
98+–23.5
65
70
135
DC
2
50
Under
Under
Under
Application Application Application
(Approved Safety Standards File No. UL:E60271, VDE: 4811.6-1171-004, CCC:2003010205034615), Last letter "U" of part number means
Pb-free product.
● MU series
Part No.
Type No. of
Approved
Standards
Rated
Functioning
Temp.✽1
(°C)
Functioning
Temp.✽2
(°C)
Maximum
Operating
Temp.✽3
(°C)
Holding
Temp.✽4
(°C)
Maximum
Temp.
Limit
(°C)✽5
AC/
DC
Electrical
Rating
Amp.
(A)
Volt.
(V)
Approved Safety
Standards
UL
VDE CCC
—
ć
—
ć
—
ć
RoHS
EYP4MU092X MU092X
92
89±2
55
55
150
DC
4
50
ć
ć
ć
( ) Under
examination
(Approved Safety Standards File No. UL:E60271, VDE: 4811.6-1171-009, CCC:2003010205034614)
✽1 Rated Functioning Temperature (UL: TF, CSA,VDE, BEAB, CCC: Tf)
The temperature at which a TCO changes its state of conductivity to open circuit with loading detection current only.
Tolerance;
PS
E
; ±7 °C
0
UL,CSA,VDE, BEAB, CCC; –10 °C
✽2 Functioning Temperature (Fusing-off temperature)
The functioning temperature at which a TCO changes its state of conductivity to open circuit in the ambient air oven which increases
temperature by 1 °C per minute and with loading the detective current 0.1 A or less.
✽3 Maximum Operating Temperature.
The maximum temperature at which a TCO can be maintained while conducting rated current for 3000 h (N, F, E, H series) or 1000 h (ML, MU
series) For details please refer to specification.
✽4 Holding Temperature (UL: TH, CSA: Th, VDE, BEAB, CCC: Tc)
The maximum temperature at which a TCO can be maintained while conducting rated current for 168 h which will not cause a change in
state of conductivity to open circuit.
✽5 Maximum Temperature Limit (UL: TM, CSA,VDE, BEAB, CCC: Tm)
The maximum temperature at which a TCO can maintains its mechanical and electrical properties without closing again for 10
minutes after a TCO has changed its state of conductivity.
■ Dimensions in mm (not to scale)
● Axial lead type
● Radial lead type
B
l
L
l
fD1
L
fd
N Series
F Series
E Series
L
9.0±1.0
6.0±1.0
5.0±0.5
Dimensions (mm)
fD
fD1
k
2.5±0.2 3 max. 38±3 (✽78±3)
1.85+–00..2105 2.2 max. 38±3 (✽68±3)
1.5±0.1 1.8 max. 38±3 (✽68±3)
fd
0.60±0.05
0.53±0.02
0.53±0.02
● Thin type
A
EB
G
D
(H)
H Series
A
5.0±0.5
Dimensions (mm)
B
C
L
4.0±0.5 2.2±0.3 55±3
fd
0.53±0.02
(✽) Long lead type
F
C
ML Series
MU Series
A
25.0±0.5
26.5±0.5
B
3.2±0.3
4.5±0.4
C
0.65±0.15
1.00±0.15
Dimensions (mm)
D
E
4.5±0.5
3.0±0.2
11.0+–00..64
3.0±0.2
F
0.10±0.02
0.15±0.02
G
10.25±0.50
7.7±0.5
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
(H)
(10.25)
(7.7)
Mar. 2005