■ Recommended Soldering Conditions
Recommendations and precautions are described below.
● Recommended soldering conditions for reflow
· Reflow soldering shall be performed a maximum of
two times.
· Please contact us for additional information when
used in conditions other than those specified.
· Please measure the temperature of the terminals
and study every kind of solder and printed circuit
board for solderability before actual use.
Peak
Preheating
Heating
Time
For soldering (Example : Sn-37Pb)
Preheating
Main heating
Peak
Temperature
140 °C to 160 °C
Above 200 °C
235 ± 10 °C
Time
60 s to 120 s
30 s to 40 s
max. 10 s
For lead-free soldering (Example : Sn/3Ag/0.5Cu)
Temperature
Time
Preheating
150 °C to 170 °C 60 s to 120 s
Main heating Above 230 °C 30 s to 40 s
Peak
max. 260 °C
max. 10 s
<Repair with hand soldering>
● Preheat with a blast of hot air or similar method. Use a soldering iron with a tip temperature of 350 °C or less. Solder
each electrode for 3 seconds or less.
● Never touch this product with the tip of a soldering iron.
Safety Precautions
The following are precautions for individual products. Please also refer to the precautions common to EMI Filters,
ESD Suppressors, Fuses, and MR Sensors shown on page EL113 of this catalog.
1. When possible, do not mount Common mode Noise Filter Array (hereafter called the filters) by flow soldering. It is
highly possible that flow soldering may cause bridges between the electrodes.
2. Use rosin-based flux or halogen-free flux.
3. For cleaning, use an alcohol-based cleaning agent. Before using any other type, consult with our sales person
in advance.
4. Do not apply shock to the filters or pinch them with a hard tool (e.g. pliers and tweezers). Otherwise, their bodies
may be chipped, affecting their performance. Excessive mechanical stress may damage the filters. Handle
with care.
5. Store the filters in a location with a temperature ranging from −5 °C to +40 °C and a relative humidity of 40 % to 60 %,
where there are no rapid changes in temperature or humidity.
6. Use the filters within half a year after the date of the outgoing inspection indicated on the packages.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.