English
Language : 

ECJ-0EC1H101J Datasheet, PDF (3/12 Pages) Panasonic Semiconductor – Multilayer Ceramic Capacitors (For General Electronic Equipment)
Multilayer Ceramic Capacitors(For General Usage)
■ Specifications and Testing Methods
Item
Operating
Temperature
Range
Dielectric
Withstanding
Voltage
Specification
Class 1
Class 2
Temp. Char. C∆
: –55 to 125 °C
: –25 to 85 °C
Temp. Char. SL
: –55 to 125 °C
Temp. Char. B, X7R
: –55 to 125 °C
Temp. Char. B, X5R
: –55 to 85 °C
Temp. Char. F, Y5V
: –30 to 85 °C
No dielectric breakdown and /or damage
Insulation
Resistance
(I R)
Capacitance
Q Factor or
Dissipation
Factor
(tan δ)
10000 Mȑ or 500/C (Mȑ) whichever is less.
Note:100/C(Mȑ)min. for DC 10 V max.
C:Nominal Cap. in µF
Within the specified tolerance.
Q:
C<30 pF: Q >400+20C
30 pF<C <1000 pF:Q >1000
tan δ:
C>1000 pF: tan δ< 0.002
(C:Nominal Cap. in pF)
tan δ:
Temp. Char. B, X7R, X5R:
0.15 max.
Temp. Char. F, Y5V:
0.2 max.
Please see the technical
specifications for details.
Temperature
Characteristics
Temp. Char.
CG : 0± 30 ppm/ °C
CH : 0± 60 ppm/ °C
CJ : 0±120 ppm/ °C
CK : 0±250 ppm/ °C
SL : +350 to –1000 ppm/ °C
Temp. Char.
B : ±10 %
X7R : ±15 %
X5R : ±15 %
F : +30, –80 %
Y5V : +22, –82 %
Adhesion
Terminal electrodes shall be free from peeling or signs of
peeling.
Test Method
Test voltage:
Class 1:Rated voltage ҂300 %
Class 2:Rated voltage ҂250 %
Duration:1 to 5 s
Charge/discharge current : 50 mA max.
Measuring voltage:Rated voltage
Duration: 60±5 s
Charge/discharge current : 50 mA max.
Measuring temperature: 20±2 °C
Class 1:
Nominal capacitance C < 1000 pF C > 1000 pF
Measuring frequency 1 MHz ± 10 % 1 kHz ± 10 %
Measuring voltage 0.5 to 5 Vrms 0.5 to 5 Vrms
Class 2:
Preconditioning: The capacitors shall be kept
in temperature of 150 +0/–10 °C for 1 hour
and subjected to standard condition✽ 48±4
hours before initial measurement.
Nominal capacitance C < 1 µF
Measuring frequency 1 kHz ± 10 %
Measuring voltage 1.0 ± 0.2 Vrms
Maximum capacitance change at stage 1 to 5
Temp.
Char.
C∆, SL
B, F
X7R
X5R
Y5V
1 20 °C 25 °C 25 °C 25 °C
2 –25 °C –55 °C –55 °C –30 °C
3
(Ref. Temp.)
20 °C
25 °C
25 °C
25 °C
4 85 °C 125 °C 85 °C 85 °C
5 20 °C 25 °C 25 °C 25 °C
See the technical specifications for
details such as measuring voltage.
Applied force:
Size: 0201: 2 N
Size: 0402 to 0805: 5N
Duration: 10 s
Size: 0201 to 0402
1.0
0.5R
0.3/Size:0201
0.5/Size:0402
Sample
PC board
Size: 0603 to 0805
✽Standard conditions : Temperature 15 to 35 °C, Relative humidity 45 to 75 %
Sample Unit : mm
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
00 Apr. 2008
– EC10 –