English
Language : 

AQCD3-IM100VAC Datasheet, PDF (3/5 Pages) Panasonic Semiconductor – Miniature DIL SSR 1A control type for PCBs Copying equipment Copying equipment
AQ-C
2. Characteristics
[Ambient temperature: 20°C 68°F; Input voltage ripple (output module) and output voltage ripple (input module): 1% or less]
1) Input module
Item
Type
AC Input module
DC Input module
Remarks
Operate time, max.
Release time, max
Insulation resistance, min.
Breakdown voltage
20 ms
20 ms
109 Ω between input and output
2,500 Vrms between input and output
0.5 ms
0.5 ms
Input voltage: 24 V DC or 100V AC
Output voltage: 24 V DC
Output current: 25mA
at 500 V DC
For 1 minute
Vibration
resistance
Destructive
Functional
10 to 55Hz double amplitude of 3 mm
10 to 55Hz double amplitude of 3 mm
1 hour for X,Y, Z, axis
10 minutes for X,Y, Z, axis
Shock
resistance
Destructive
Functional
Ambient temperature
Storage temperature
Min. 980 m/s2 {100 G}
Min. 980 m/s2 {100 G}
–30°C to +80°C –22°F to +176°F
–30°C to +100°C –22°F to +212°F
5 time each for X,Y,Z axis
4 time each for X,Y,Z axis
2) Output module
Type
Item
Operate time, max.
Release time, max.
Insulation resistance, min.
Breakdown voltage
Vibration
resistance
Destructive
Functional
Shock
resistance
Destructive
Functional
Ambient temperature
Storage temperature
Operational method
AC output
Random
Zero-cross
1 ms
1/2 cycle of voltage sine wave + 1ms
1/2 cycle of voltage sine wave + 1ms
109Ω between input and output
2,500 Vrms between input and output
10 to 55Hz double amplitude of 3 mm
10 to 55Hz double amplitude of 3 mm
Min. 980 m/s2 {100 G}
Min. 980 m/s2 {100 G}
–30°C to +80°C –22°F to +176°F
–30°C to +100°C –22°F to +212°F
Random Turn-ON,
Zero-cross (Turn-OFF)
Zero-cross (Turn-ON and Turn-OFF)
DC output
0.5 ms
1 ms
Remarks
at 500 V DC
For 1 minute
1 hour for X,Y, Z, axis
10 minutes for X,Y, Z, axis
5 time each for X,Y,Z axis
4 time each for X,Y,Z axis
—
REFERENCE DATA
1. Load current vs. ambient temperature
characteristics
(AC/DC output)
Use load current within range specified in the figure
below
2.-(1) Non-repetitive surge current vs. carrying
time characteristics
(AC output)
2.-(2) Non-repetitive surge current vs. carrying
time characteristics
(DC output)
1.0
5
0.8
30
4
0.6
20
3
0.4
2
10
0.2
1
0
–30 0
20 40 60 80
Ambient temperature, °C
0 1 2 3 4 5 7 10 20 30 40 50 70 100
No. of cycles at 60 Hz
010 20 30 4050 70 100 200 300
Carrying time, ms
1,000
3. Input current vs. input voltage characteristics
(AC/DC output)
30
AC output
DC output
25
20
15
10
5 (5 V type) (12 V type) (24 V type)
0
0
10
20
30
Input voltage, V
4.-(1) Input current vs. input voltage
characteristics
(AC input)
10
8
6
4
2
0
100
200
300
Input voltage, V AC
4.-(2) Input current vs. input voltage
characteristics
(DC input)
10
9
8
7
6
5
4
3
2
1
0
5 10 15 20 25 30 35
Input voltage, V DC
ASCTB214E 201201-T1
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/