English
Language : 

JC1AF-DC6V-F Datasheet, PDF (2/5 Pages) Panasonic Semiconductor – Wide variation 1a 15A, 2a 10A power relays High inrush current capability
JC
RATING
1. Coil data
Contact Nominal coil
arrangement voltage
1 Form A
2 Form A
6V DC
12V DC
24V DC
6V DC
12V DC
24V DC
Pick-up voltage
(at 20°C 68°F)
80%V or less of
nominal voltage
(Initial)
Drop-out voltage
(at 20°C 68°F)
10%V or more of
nominal voltage
(Initial)
Nominal operating
current
[±10%] (at 20°C 68°F)
150 mA
75 mA
37.5mA
166.6mA
83.3mA
41.6mA
Coil resistance
[±10%] (at 20°C 68°F)
40Ω
160Ω
640Ω
36Ω
144Ω
576Ω
Nominal operating
power
0.9W
0.9W
0.9W
1.0W
1.0W
1.0W
Max. applied voltage
(at 60°C 140°F)
110%V of
nominal voltage
2. Specifications
Characteristics
Item
Specifications
Contact
Contact material
Arrangement
Contact resistance (Initial)
Contact force
AgSnO2 type
1 Form A
2 Form A
Max. 100 mΩ (By voltage drop 6 V DC 1A)
Min. 30 g
Nominal switching capacity (resistive load)
15A 250V AC
10A 250V AC
Max. switching power (resistive load)
3,750VA
2,500VA
Rating
Max. switching voltage
Max. switching current
250V AC
15A
10A
Nominal operating power
900mW
1,000mW
Min. switching capacity (reference value)*1
Insulation resistance (Initial)
Between open contacts
100mA, 5V DC
Min. 100MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
2,000 Vrms for 1 min. (Detection current: 10 mA)
Breakdown voltage
(Initial)
Between contacts sets
—
2,000 Vrms for 1 min.
(Detection current: 10 mA)
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Between contact and coil
Temperature rise (coil)
Surge breakdown voltage*2
(Between contact and coil) (Initial)
Operate time (at nominal voltage) (at 20°C 68°F)
Release time (at nominal voltage) (at 20°C 68°F)
Shock resistance
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical (at 180 times/min.)
Electrical (at 20 times/min.)
Conditions for operation, transport and storage*3
Max. operating speed
4,000 Vrms for 1 min. (Detection current: 10 mA)
Max. 55°C 131°F (By resistive method, nominal coil voltage applied to the coil, at 60°C 140°F)
10,000 V
Max. 30 ms (excluding contact bounce time.)
Max. 10 ms (excluding contact bounce time) (Without diode)
196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 2.0 mm
Min. 5×106
Min. 105 (10A 250V AC at rated load), Min. 105 (5A 250V AC at rated load)
Ambient temperature: –50°C to +60°C –58°F to +140°F,
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at nominal switching capacity)
Unit weight
Approx. 31 g 1.09 oz
* Specifications will vary with foreign standards certification ratings.
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
JC1a type
1. Maximum value for switching capacity
AC resistive load
15
10
DC resistive load
1
AC
inductive
load
(cosϕ = 0.4)
DC inductive load
(L/R = 7 ms)
0.1
1
10
100 400
Contact voltage, V
2. Operate / release time
26
25
24
23
22
21
20
19
18
17
16
Operate time
15
14
13
12
Max.
11
10
Min.
9
4
3
Release time
2
1
0
80
100
Max.
Min.
120
Coil applied voltage, %V
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
ASCTB79E 201201-T