HC1-H-AC6V-F Datasheet, PDF (10/18 Pages) Panasonic Semiconductor – Relay for control panel of 1A to 10A (1c/2c/3c/4c) Full range of types
HC
3. Keep relay
1) Coil data
(1) AC coils (50/60Hz)
Contact
arrangement
2 Form C
Nominal
coil
voltage
6V AC
12V AC
24V AC
48V AC
100V AC
Set voltage
(at 20°C 68°F)
80%V or less of
nominal voltage
(Initial)
Reset voltage
(at 20°C 68°F)
80%V or less of
nominal voltage
(Initial)
Nominal operating current
[±10%] (at 20°C 68°F)
Set coil
Reset coil
206mA
103mA
100mA
52mA
51mA
21.4mA
25.2mA
18.5mA
13.3mA
7.1mA
Nominal operating power
Set coil
1.23VA
1.20VA
1.22VA
1.20VA
1.33VA
Reset coil
0.62VA
0.62VA
0.51VA
0.88VA
0.71VA
Max. applied
voltage
(at 50°C 122°F)
110%V of
nominal voltage
(2) DC coils
Contact
arrangement
2 Form C
Nominal
coil
voltage
6V DC
12V DC
24V DC
48V DC
100V DC
Set voltage
(at 20°C 68°F)
80%V or less of
nominal voltage
(Initial)
Reset voltage
(at 20°C 68°F)
80%V or less of
nominal voltage
(Initial)
Nominal operating current
[±10%] (at 20°C 68°F)
Set coil
Reset coil
207mA
107mA
100mA
52.2mA
51.1mA
25.5mA
25.3mA
13.7mA
15.6mA
5.8mA
Coil resistance
[±10%] (at 20°C 68°F)
Set coil
Reset coil
29Ω
56Ω
120Ω
230Ω
470Ω
941Ω
1,897Ω
3,504Ω
6,410Ω
17,241Ω
Nominal operating power
Set coil
1.24W
1.20W
1.23W
1.21W
1.56W
Reset coil
0.64W
0.63W
0.61W
0.66W
0.58W
Max. applied
voltage
(at 50°C 122°F)
110%V of
nominal voltage
Notes: 1. The allowable coil resistance range is ±10% when within 1,000Ω and ±15% when. 1,000Ω or higher.
2. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2) Specifications
Characteristics
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Item
Contact resistance (Initial)
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching current
Nominal operating power
Min. switching capacity (Reference value)*1
Breakdown voltage (Initial) Between contact and coil
Temperature rise (coil)
Set time/Reset time (at 20°C 68°F)
Shock resistance
Functional
Mechanical
Electrical
Ambient temperature
Specifications
Max. 50 mΩ (By voltage drop 6 V DC 1A)
3A 250V AC
750VA
3A
Set coil: 1.20VA to 1.33VA; Reset coil: 0.51VA to 0.88VA
100µA 100mV DC
1,500 Vrms for 1min.
Set coil: Max. 80°C 176°F; Reset coil: Max. 50°C 122°F (at nominal coil voltage)
Approx. 20ms/30ms (at nominal coil voltage)
Min. 98m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Min. 107 (at 180 times/min.)
Min. 2×105 rated load (at 20 times/min.)
–40°C to +50°C –40°F to +122°F (Not freezing and condensing at low temperature)
Notes: *1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Other specifications are same as standard type HC relay. Please see the standard type HC relay.
*3. Please maintain (reset) the relay more than once a year. Leaving it in the set position for long periods of time will cause the magnet to attenuate over the years.
This will decrease the holding power and cause failure of the set position.
4. With diode type (For DC)
1) Coil data
Same coil data as HC relay standard type for DC. Please refer to standard type information.
Please connect DC coil type built-in diode correctly by verifying the coil polarity.
2) Specifications
Characteristics
Item
Specifications
Conditions
Conditions for operation, transport and storage*
Ambient temperature: –50°C to +60°C –58°F to +140°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Notes: Other specifications are same as standard type HC relay. Please see the standard type HC relay.
* The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
5. With CR circuit type
1) Coil data
Same coil data as HC relay standard type for AC. Please refer to standard type information.
2) Specifications
Characteristics
Item
Specifications
Electrical characteristics
Conditions
Temperature rise (coil)
Conditions for operation, transport and storage*
Max. 90°C 194°F (By resistive method, nominal voltage, rated current at 60°C 140°F)
Ambient temperature: –50°C to +60°C –58°F to +140°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Notes: Other specifications are same as standard type HC relay. Please see the standard type HC relay.
* The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e