SFS6-PS Datasheet, PDF (1/9 Pages) Panasonic Semiconductor – Slim compact safety relay | |||
|
Slim compact safety relay
SFS
SF RELAYS
Slim type
Max. 40
1.575
Max. 24
.945
Max. 50
1.969
Max. 24
.945
Max. 13
.512
Max. 13
.512
mm inch
FEATURES
⢠Forcibly guide contact structure
(EN50205 Class A TÃV recognized)
⢠Slim profile (mm inch)
Compact size with slim profile relay
reduces substrate size.
[4-pole type]40 (L)ï´13 (W)ï´24 (H)
1.575 (L)ï´.512 (W)ï´.945 (H)
[6-pole type]50 (L)ï´13 (W)ï´24 (H)
1.969 (L)ï´.512 (W)ï´.945 (H)
⢠Built-in LED indication type available
Built-in LED eliminates need for design
and mounting of separate LED circuit.
This cuts costs and saves labor.
⢠Fast response time is achieved
(8 ms or less)
Circuit is quickly opened to ensure
safety.
⢠High shock resistance
(Functional: Min. 200m/s2)
Improved anti-shock properties
meaning that the relay can be safely
used in high shock and vibration
environments such as in machine tools
and other factory equipment.
⢠PC board sockets also available
(4 and 6-poles)
⢠Lineup also includes DIN terminal
socket with finger protect construction
(4 and 6-poles)
TYPICAL
APPLICATIONS
⢠Machine tools
⢠Robots
⢠Safety PLCs
⢠Circuits with stringent safety standard
requirements such as those in motor
vehicle production equipment.
SPECIFICATIONS
Contact
Item
4 poles
6 poles
Contact arrangement
2 Form A/2 Form B
3 Form A/1 Form B
4 Form A/2 Form B
5 Form A/1 Form B
3 Form A/3 Form B
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
100 mï
Contact material
Gold-flashed AgSnO2 type
Nominal switching capacity
6 A 250 V AC, 6 A 30 V DC
Max. switching power
1,500 VA, 180 W
Rating (resistive load)
Max. switching voltage
Max. switching current
250 V AC, 30 V DC
6 A (Reduce by 0.1 A/ï°C for temperatures 70 to 85ï°C.)
Min. switching capacity
(Reference value) #1
1 mA 5 V DC
Mechanical (at 180 times/min.)
107
250 V AC 6 A resistive load: 105 (at 20 times/min.)
Expected life
(min. operations)
Electrical
30 V DC 6 A resistive load: 105 (at 20 times/min.)
250 V AC 1 A resistive load: 5ï´105 (at 30 times/min.)
30 V DC 1 A resistive load: 5ï´105 (at 30 times/min.)
[AC 15] 240 V AC 2 A inductive load: 105 (at 20 times/min., cosïª = 0.3)
[DC 13] 24 V DC 1 A inductive load: 105 (at 20 times/min., L/R = 48 ms)
#1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
ds_61410_en_sfs: 031213D