English
Language : 

OH10010 Datasheet, PDF (1/2 Pages) Panasonic Semiconductor – GaAs Hall Device
GaAs Hall Devices
OH10010
GaAs Hall Device
Magnetic sensor
I Features
• Hall voltage: typ. 105 mV (VC = 6 V, B = 0.1 T)
• Input resistance: typ. 0.75 kΩ
• Satisfactory linearity of GaAs hall voltage with respect to the
magnetic field
• Small temperature coefficient of the hall voltage: β ≤ − 0.06%/°C
• Mini type (4-pin) package with positioning projection. Allowing
automatic insertion through the magazine package.
I Applications
• Various hall motor (VCR, phonograph, VD, CD, and FDD)
• Automotive equipment
• Industrial equipment
• Applicable to wide-varying field (OA equipment, etc.)
I Absolute Maximum Ratings Ta = 25°C
Parameter
Symbol
Rating
Unit
Control voltage
Power dissipation
Operating ambient temperature
Storage temperature
VC
12
V
PD
150
mW
Topr
−30 to +125
°C
Tstg
−55 to +125
°C
Unit : mm
0.65 ± 0.15
2.8
+
−
0.2
0.3
1.5 ± 0.2
0.65 ± 0.15
4
1
0.5 R
3
2
0 to 0.1
0.4 ± 0.2
0.4 ± 0.2
φ 1.0 ± 0.025
1 : VH Output (−) side
2 : VC Input (−) side
3 : VH Output (+) side
4 : VC Input (+) side
Mini Type Package (4-pin) with positioning projection
Marking Symbol: ON
I Electrical Characteristics Ta = 25°C
Parameter
Hall voltage*1
Unequilibrium ratio*2, 4
Input resistance
Output resistance
Temperature coefficient of hall voltage
Temperature coefficient of input
resistance
Symbol
VH
VHO
RIN
ROUT
β
α
Conditions
VC = 6 V, B = 0.1 T
VC = 6 V, B = 0 T
IC = 1 mA, B = 0 T
IC = 1 mA, B = 0 T
IC = 6 mA, B = 0.1 T
IC = 1 mA, B = 0 T
Min Typ Max Unit
80 105 130 mV
±19 mV
0.5 0.75
kΩ
1.5
5
kΩ
−0.06 %/°C
0.3 %/°C
Linearity of hall voltage*3
γ
IC = 6 mA, B = 0.1 T/0.5 T
2
%
Note)
*1 : VH =
VH++VH−
2
*2 : Output pin voltage under no-load (B = 0) condition
*3 : The linearity γ of VH is a percentage of a difference between cumulative sensitivity of KH1 and KH5 which are measured
respectively at B = 0.1 T and 0.5 T to their average. That is,
γ=
KH5−KH1
1/2(KH1+KH5)
(the cumulative sensitivity KH =
VH
ICɾB
)
*4 : VHO rank classification
Class
A
B
VHO (mV) +19 to +9 +12 to +2
C
+5 to −5
D
−2 to −12
E
−9 to −19
1