English
Language : 

EEC-SE0H104 Datasheet, PDF (1/1 Pages) Panasonic Semiconductor – Electric Double Layer Capacitors (Gold Capacitor)/ SE
Electric Double Layer Capacitors (Gold Capacitor)/ SE
Stacked Coin Type
Series: SE
■ Features
● Endurance : 70 °C 1000 h
● Automatic insertion available
● RoHS directive compliant
■ Recommended Applications
● Memory back-up for video and audio equipment,
cameras, telephones, printers, data terminals,
rice cookers and intelligent remote controls.
■ Specifications
Category Temp. Range
–25 °C to +70 °C
Maximum Operating Voltage
5.5 V.DC
Nominal Cap.Range
0.022 F to 0.22 F
Characteristics at Low
Temperature
Capacitance change ±30 % of initial measured value at +20 °C (at –25 °C)
Internal resistance <5 times of initial measured value at +20 °C (at –25 °C)
After 1000 hours application of 5.5 V. DC at +70 °C, the capacitor shall meet the following limits.
Endurance
Capacitance change ±30 % of initial measured value
Internal resistance <4 times of initial specified value
Shelf Life
After 1000 hours storage at +70°C without load, the capacitor shall meet the specified
limits for Endurance.
■ Dimensions in mm(not to scale)
5.4±0.8
P2
P
oh
P1 F
–
+
φd
P0
φD0
oh1
–
+
(Unit : mm)
Dimensions
φd
P0
F
W
W0
W1
W2
H0
φD0
P
P1
P2
ͬh, ͬh1
H1
Nominal
0.55
12.7
5.0
18.0
5.5<
9.0
0 to 3.0
16.4
4.0
12.7
3.85
6.35
0
30.3>
Tolerance
±0.05
±0.2
+0.8
–0.2
±0.5
–
±0.5
–
±0.5
±0.2
±1.0
±0.50
±1.00
±1.0
–
■ Standard Products
Maximum
Operating Voltage
Capacitance
(V.DC)
(F)
0.022
0.047
5.5
0.10
0.22
Capacitance
tolerance
(F)
0.0176 to 0.0396
0.0376 to 0.0846
0.080 to 0.180
0.176 to 0.396
Internal resistance
(Initial specified value)
(ȑ) at 1kHz
< 150
< 120
< 75
< 75
Part number
EECSE0H223
EECSE0H473
EECSE0H104
EECSE0H224
Min. Packaging
Q’ty
(pcs)
1000
1000
1000
1000
Note: 1. When ordering please observe the minimum packaging quantity.
2. When the surface mount component goes through UV or a heat oven to affix the adhesive glue, the capacitor’s surface
temperature should not exceed 100 °C for more than 60 seconds (maximum temperature should not exceed 105 °C)
3. Do not use reflow soldering. (IR, Atmosphere heating methods, etc.)
Please refer to the page of “Application Guidelines”.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Feb. 2013
– EEC-6 –