English
Language : 

DE1A1B-L-3V Datasheet, PDF (1/5 Pages) Panasonic Semiconductor – COMPACT HIGH-INSULATION POLARIZED POWER RELAY
DE (ADVEDE)
COMPACT
HIGH-INSULATION DE RELAYS (ADE)
POLARIZED POWER RELAY
12.5
FEATURES
25.0
.984
.492
• Conforms to European safety
• Low operating power
12.5
standards (VDE0700 and VDE0631)
Nominal operating power at 200 mW
.492
Insulating distance between coil and
(Single side stable, 2 coil latching)
contacts:
• Compact body saves space
Clearance Min. 8mm .315 inch
Creepage distance Min. 8mm .315 inch
Size: 12.5(W)  25.0(L)  12.5(H) mm
.492(W)  .984(L)  .492(H) inch
mm inch
• Extensive product line-up
• UL/CSA, VDE approved
• Surge voltage between contact and
coil 12 kV
SPECIFICATIONS
Contact
Arrangement
1 Form A
1 Form A
1 Form B
2 Form A
Contact material
AgSnO2 type
Initial contact resis-
tance, max. (By voltage
drop 6V DC 1A)
30m
Nominal
switching
capacity
10A 250V AC, 8A 250V AC, 8A 250V AC,
10A 30V DC 8A 30V DC 8A 30V DC
Max.
switching
power
2,500 VA*, 2,000 VA*, 2,000 VA*,
300W
240W
240W
Rating
(resistive
load)
Max.
switching
voltage
440V AC,
230V DC
440V AC,
230V DC
440V AC,
230V DC
Max.
switching
current
10A (16A)* 8A (16A)*
8A (16A)*
Min. switch-
ing capac-
ity#1
100 mA, 5 V DC
Mechanical
(at 300cpm)
107
Expected
life (min.
operations)
Electrical
(at 20 cpm)
(resistive load)
Electrical
(16A / 230 V
AC resistive)*
105
25000
105(AC)
5  104(DC)
20000
Coil (at 20C, 68F)
Single side stable
1 coil latching
2 coil latching
Nominal operating power
200 mW
100 mW
200 mW
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Characteristics
Max. operating speed
Initial insulation resistance*1
Initial
breakdown
voltage*2
Between open contacts
Between contact sets
Between contact and coil
Surge voltage between contact and coil*3
Operate time [Set time]*4
Release time (without diode) [Reset time]*4
Temperature rise (at 70C)*5
Shock resistance
Functional*6
Destructive*7
Vibration resistance
Functional*8
Destructive
Conditions for operation,
transport and storage*9
(Not freezing and condens-
ing at low temperature)
Unit weight
Ambient temp.
Humidity
20 cpm (at rated load)
Min. 1,000 M
(at 500 V DC)
1,000 Vrms
4,000 Vrms (2 Form A,
1 Form A 1 Form B)
5,000 Vrms
Min. 12,000 V (initial)
Max. 10ms (typ. 5ms)
[Max. 10ms (typ. 4ms)]
(at 20C 68F)
Max. 5ms (typ. 2ms)
[Max. 10ms (typ. 4ms)]
(at 20C 68F)
Max. 50C
Min. 196 m/s2{20 G}
Min. 980 m/s2{100 G}
10 to 55 Hz at double
amplitude of 2 mm
10 to 55 Hz at double
amplitude of 3 mm
–40C to 70C
–40F to 158F
5 to 85% R.H.
Approx. 7 g .25 oz
Remarks
* 16A possible for one contact set only with max. 4000 VA switching power.
*1 Measurement at same location as “Initial breakdown voltage” section.
*2 Detection current: 10mA
*3 Wave is standard shock voltage of 1.2  50s according to JEC-212-1981
*4 Nominal operating voltage applied to the coil, excluding contact bounce time.
*5 By resistive method
*6 Half-wave pulse of sine wave: 11ms, detection time: 10ms.
*7 Half-wave pulse of sine wave: 6ms
*8 Detection time: 10ms
*9 Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT
ENVIRONMENT section in Relay Technical Information.
ds_61A01_en_de: 100811D
1