LF (ALVFDE)
LF RELAYS (ALF) Load for air conditioner
1a 20A power relays
TMP type
PCB type
RoHS compliant
FEATURES
1. Ideal for compressor and inverter
loads
1) Compressor load: 20A 250V AC
2) Inverter load: 20A 100V AC,
10A 200V AC
2. High insulation resistance
• Creepage distance and clearances
between contact and coil;
Creepage Min. 9.5mm .374inch/
Clearance Min. 8mm .315inch
• Surge withstand voltage: 10,000V
3. “PCB” and “TMP” types available
4. Conforms to the various safety
standards:
UL/C-UL, TÜV and VDE approved
ORDERING INFORMATION
ALF
LF relay
Contact arrangement
1: 1 Form A
Terminal shape
T: TMP type
P: PCB type
Nominal coil voltage, V DC
05: 5, 06: 6, 09: 9, 12: 12, 18: 18, 24: 24
Note: Certified by UL/C-UL,VDE and TÜV
TYPICAL APPLICATIONS
• Air conditioner
• Refrigerators
• OA equipment
TYPES
Contact arrangement
Nominal coil voltage
5V DC
6V DC
1 Form A
9V DC
12V DC
18V DC
24V DC
Standard packing: Carton 50 pcs., Case 200 pcs.
TMP type
ALF1T05
ALF1T06
ALF1T09
ALF1T12
ALF1T18
ALF1T24
Part No.
PCB type
ALF1P05
ALF1P06
ALF1P09
ALF1P12
ALF1P18
ALF1P24
RATING
1. Coil data
Nominal coil
voltage
5V DC
6V DC
9V DC
12V DC
18V DC
24V DC
Pick-up voltage
(at 20°C 68°F)
70%V or less of
nominal voltage
(Initial)
Drop-out voltage
(at 20°C 68°F)
10%V or more of
nominal voltage
(Initial)
Nominal operating
current
[±10%] (at 20°C 68°F)
180 mA
150 mA
100 mA
75 mA
50 mA
37.5mA
Coil resistance
[±10%] (at 20°C 68°F)
27.8Ω
40 Ω
90 Ω
160 Ω
360 Ω
640 Ω
Nominal operating
power
(at 20°C 68°F)
900mW
Max. applied voltage
(at 20°C 68°F)
110%V of
nominal voltage
ASCTB195E 201202-T