English
Language : 

EEC-RG0V224H Datasheet, PDF (1/1 Pages) Pacific Silicon Sensor,Inc. – Electric Double Layer Capacitors (Gold Capacitor)/ RG
Electric Double Layer Capacitors (Gold Capacitor)/ RG
Stacked Coin Type
Series: RG
■ Features
● Endurance: 85 °C 2000 h
● Can be discharged mA current
● RoHS directive compliant
■ Recommended Applications
● Backup of data/RTC of base station, electronic meter,
and industrial equipment
● For assist of rapid load change
■ Specifications
Category temp. range
–25 °C to +85 °C
Maximum operating voltage
3.6 V DC
Nominal capacitance
0.22 F
1.0 F
Capacitance tolerance
–20 % to +80%
Characteristics at Low
Temperature
Capacitance change ±30 % of initial measured value at +20 °C (at –25 °C)
Internal resistance <5 times of initial measured value at +20 °C (at –25 °C)
After 2000 hours application of maximum operating voltage at +85 °C
Endurance Capacitance change ±30 % of initial measured value at 20 °C ±30 % of initial measured value at 20 °C
Internal resistance
100 ȑ or less
40 ȑ or less
After 2000 hours storage at +85 °C without load (voltage)
Shelf life Capacitance change
Capacitance change shall meet the specified limits for Endurance
Internal resistance
Internal resistance shall meet the specified limits for Endurance
■ Dimensions in mm(not to scale)
RG series 0.22(F)
Terminal : V
10.5 max.
5.0 max.
Terminal : H
Sleeve
RG series 1.0(F)
(Unit : mm)
Terminal : V
φ19.0±0.3
5.5±0.5
Terminal : H
Sleeve
0.8±0.05
(1.7)
0.2±0.05
5.0±0.8
11.5 max.
0.2±0.05
10.0±0.5
0.8±0.05
(1.7)
20.5 Max.
φ19.0±0.3
–
1.0±0.1 5.0±0.5
+
0.20±0.05
20.0±0.5
0.2±0.05 1.0±0.1
■ Standard Products
Maximum
operating
voltage
Capacitance
(V DC)
(F)
Internal resistance
(Initial specified value)
(ȑ) at 1 kHz
Recommended
discharge current
(mA)
Parts number
Mass
(g)
Min. packaging
Q'ty
(pcs)
0.22
3.6
1.0
<50
1 or less
EECRG0V224()
1.0
200
<20
20 or less
EECRG0V105()
4.1
100
Do not use reflow sp;dering.(IR, Atmospherheating methods, etc.) Please refer to the page of “Application Guidelines”.
( ): Please use V or H to indicate terminal type.
The recommended discharge current is a reference value. Please design your equipment(circuit) in consideration of IR dorop.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
– EEC-2 –
00 Nov. 2012