ENVIRONMENTAL SPECIFICATIONS
Parameter
Conditions
Operating case temperature
Maximum case temperature
Over temperature protection
Storage temperature range
Thermal impedance (1)
Vertical direction by natural convection (20LFM)
Only mount on the iron base-plate
Mount on the iron base-plate and top side with 7G-0058A Heat-sink
Thermal shock
Shock
Vibration
Relative humidity
Min.
-40
-55
Typ.
+100
+110
Max.
+100
+125
U℃nit
℃℃
2.55
℃/W
2.0
MIL-STD-810F
EN61373, MIL-STD-810F
EN61373, MIL-STD-810F
5% to 95% RH
EMC SPECIFICATIONS
Parameter
EMI (2)
ESD
Radiated immunity
Fast transient (3)
Surge (3)
Conducted immunity
EN55011, EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Conditions
Air ± 8kV and Contact ± 6kV
10 V/m
± 2kV
EN55024 ±1kV and EN50155 ±2kV
10 Vr.m.s
Level
DC-DC module
Class A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Note:
1. (1)The iron base-plate dimension is 19” * 3.5” * 0.063” (The height is EIA standard 2U).
(2)The heat-sink is optional and P/N is 7G-0058A-F.
2. The standard modules meet EMI Class A without external components.
3. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter capacitor Power Mate suggest: WAF(D)150-24S W : Nippon chemi-con KY series, 470µF/50V.
WAF(D)150-24S W :: Nippon chemi-con KY series, 220µF/100V.
WAF(D)150-110S W : Nippon chemi-con KXJ series, 150µF/200V.
CAUTION: This power module is not internally fused; an input line fuse must always be used. If the load was having sourcing capability (Ex: Battery or
Super Capacitor), an output line fuse must always be used.
CHARACTERISTIC CURVE
WAF(D)150-48S24W Derating Curve (Note 1)
WAF(D)150-48S24W Derating Curve (Note 1)
With Heat-sink
WAF(D)150-48S24W Efficiency vs. Input Voltage
WAF(D)150-48S24W Efficiency vs. Output Load
3
www.PDUKE.com
2014/05/19