PDL06W_14 Datasheet, PDF (3/4 Pages) Power Mate Technology Co., LTD – DC-DC CONVERTER
PDL06W
ENVIRONMENTAL SPECIFICATIONS
Parameter
Operating ambient temperature
Storage temperature range
Thermal shock
Vibration
Relative humidity
Conditions
Standard type
Suffix “H”
Suffix “M”
Without derating
With derating
Without derating
With derating
Without derating
With derating
Min.
-40
+71
-40
+71
-40
+75
-55
Typ.
Max. Unit
+71
+100
+71
+100
℃
+75
+100
+125
℃
MIL-STD-810F
MIL-STD-810F
5% to 95% RH
EMC SPECIFICATIONS
Parameter
EMI(1)
ESD
Radiated immunity
Fast transient (2)
Surge (2)
Conducted immunity
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Conditions
Air ± 8kV and Contact ± 6kV
20 V/m
± 2kV
±2kV
10 Vr.m.s
, Level
Class A Class B
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Note:
1. The standard modules meet EMI Class A or Class B with external components. For further information, please contact with P-DUKE.
2. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter Power Mate suggested:
The PDL06-24 W recommended an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS (SMDJ70A, 70V,
3000Watt peak pulse power) to connect in parallel.
The PDL06-48 W recommended an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS (SMDJ120A,
120V, 3000Watt peak pulse power) to connect in parallel.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
CHARACTERISTIC CURVE
PDL06-48S05W Derating Curve
PDL06-48S05WM Derating Curve
PDL06-48S05W Efficiency vs. Input Voltage
PDL06-48S05W Efficiency vs. Output Load
3
www.PDUKE.com