PDL03
GENERAL SPECIFICATIONS
Parameter
Conditions
Isolation voltage
1 minute
Input to Output Standard Type
Suffix ”H”
Isolation resistance
500VDC
Isolation capacitance
Standard Type
Suffix ”H”
Switching frequency
Full load to minimum load
Safety approvals
Case material
Base material
Potting material
Weight
MTBF
MIL-HDBK-217F
Min.
1600
3000
1
100
Typ. Max. Unit
VDC
GΩ
200
40
pF
kHz
UL60950-1
EN60950-1
IEC60950-1
Non-conductive black plastic
None
Silicone (UL94 V-0)
4.8g (0.17oz)
4.871 x 106 hrs
ENVIRONMENTAL SPECIFICATIONS
Parameter
Operating ambient temperature
Storage temperature range
Thermal shock
Vibration
Relative humidity
Conditions
Without derating
With derating
Min.
-40
+71
-55
Typ.
Max. Unit
+71
℃
+100
+125
℃
MIL-STD-810F
MIL-STD-810F
5% to 95% RH
EMC SPECIFICATIONS
Parameter
EMI(2)
ESD
Radiated immunity
Fast transient (3)
Surge (3)
Conducted immunity
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Conditions
Air ± 8kV and Contact ± 6kV
10 V/m
± 2kV
±1kV
10 Vr.m.s
, Level
Class A Class B
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Note:
1. It will not damage the device without installing external input capacitors. It’s helpful to reduce input reflected ripple current if external input
capacitors are installed.
2. The standard modules meet EMI Class A or Class B with external components. For further information, please contact with P-DUKE.
3. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter capacitor Power Mate suggest: Nippon chemi-con KY series, 220µF/100V.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
CHARACTERISTIC CURVE
PDL03-48S05 Derating Curve
PDL03-48S05 Efficiency vs. Input Voltage
PDL03-48S05 Efficiency vs. Output Load
3
www.PDUKE.com
2014/04/30