ENVIRONMENTAL SPECIFICATIONS
Parameter
Operating ambient temperature
Conditions
Maximum case temperature
Storage temperature range
Thermal impedance
Vertical direction by natural convection (20LFM)
Thermal shock
Vibration
Relative humidity
Without derating
With derating
Min.
-40
+81
-55
Without heat-sink
With heat-sink
Typ.
16.18
15.13
Max. Unit
+81
℃
+105
105
+125
℃℃
℃/W
MIL-STD-810F
MIL-STD-810F
5% to 95% RH
EMC SPECIFICATIONS
Parameter
EMI (3)
ESD
Radiated immunity
Fast transient (4)
Surge (4)
Conducted immunity
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Conditions
Air ± 8kV and Contact ± 6kV
10 V/m
± 2kV
± 1kV
3 Vr.m.s
Level
Class A, Class B
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Note:
1. Test by minimum input and constant resistive load.
2. Trimming allows the user to increase or decrease the output voltage set point of the module. This is accomplished by connecting an external
resistor between the Trim pin and either the +Vout pin or the -Vout pin.
3. The standard modules meet EN55022 Class A without external components and meet Class B with external components.
For further information, please contact with P-DUKE.
4. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter capacitor Power Mate suggest: Nippon chemi-con KY series, 220µF/100V.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
CHARACTERISTIC CURVE
LCD10-48S05W Derating Curve
LCD10-48S05W Derating Curve With Heat-sink
LCD10-48S05W Efficiency vs. Input Voltage
LCD10-48S05W Efficiency vs. Output Load
3
www.PDUKE.com
2014/04/30