English
Language : 

DFEC60_14 Datasheet, PDF (3/3 Pages) Power Mate Technology Co., LTD – DC-DC CONVERTER
ENVIRONMENTAL SPECIFICATIONS
Parameter
Operating ambient temperature
Storage temperature range
Thermal shock
Vibration
Relative humidity
EMC SPECIFICATIONS
Parameter
EMI
ESD
Radiated immunity
Fast transient
Surge
Conducted immunity
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Note:
1. Test by minimum input and constant resistive load.
CHARACTERISTIC CURVE
Conditions
Without derating
With derating
Min.
-40
+55
-40
Typ.
Max. Unit
+55
℃
+85
+105
℃
MIL-STD-810F
MIL-STD-810F
5% to 95% RH
Conditions
Air ± 8kV and Contact ± 6kV
10V/m
± 2kV
± 1kV
10Vr.m.s
Level
Class B
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
DFEC60-48S05 Derating Curve
MECHANICAL DRAWING
DFEC60-48S05 Efficiency vs. Input Voltage
DFEC60-48S05 Efficiency vs. Output Load
PIN CONNECTION
PIN
SINGLE
1
Ctrl
2
-Vin
3
-Vin
4
+Vin
5
NC
6
-Vout
7
+Vout
8
NC
: * NC No Connection
* Screw terminals –
wire range from 14 to 18 AWG
1. All dimensions in Inch (mm)
2. Tolerance : X.XX±0.02 (X.X±0.5)
4. Tolerance : X.XXX±0.01 (X.XX±0.25)
- - 3. Terminal screw locked torque :
MAX 2.5kgf cm (0.25N m)
3
www.PDUKE.com
2014/4/30