English
Language : 

QEB75-24S3P3 Datasheet, PDF (2/4 Pages) Power Mate Technology Co., LTD – 75 WATTS MAXIMUM OUTPUT POWER
Model
Number
QEB75-24S3P3
QEB75-24S05
QEB75-24S12
QEB75-24S15
QEB75-48S1P8
QEB75-48S2P5
QEB75-48S3P3
QEB75-48S05
QEB75-48S12
QEB75-48S15
Input
Range
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
Output Output Current
Output (4)
Input Current Eff (4) Load
Voltage Min. load Full load Ripple & Noise No load(3) Full load(2) (%) regulation
3.3 VDC
5 VDC
12 VDC
15 VDC
1.8 VDC
2.5 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
20A
15A
6.25A
5A
25A
25A
20A
15A
6.25A
5A
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
80mA
130mA
190mA
190mA
50mA
50mA
70mA
80mA
130mA
130mA
3198mA
89
3634mA
90
3662mA
90
3634mA
90
1157mA
85
1569mA
87
1599mA
90
1817mA
90
1831mA
90
1817mA
90
10mV
15mV
36mV
45mV
5.4mV
7.5mV
10mV
15mV
36mV
45mV
Note :
1.BELLCORE TR-NWT-000332. Case 1: 80% Stress, Temperature at 40ºC.
MIL-HDBK-217F Notice2 @Ta=25 ºC, Full load(Ground, Benign, controlled environment)
2.Maximum value at nominal input voltage and full load of standard type.
3.Typical value at nominal input voltage and no load.
4.Typical value at nominal input voltage and full load.
5.Maximum output deviation is 10% inclusive of trim. If remote sense is not being used, the + sense should be connected to its corresponding
+OUTPUT and likewise the –sense should be connected to its corresponding –OUTPUT.
6.The positive logic and pin length are optional ( see table ). The pin voltage is referenced to –Vin.
7.Heat sink is optional and P/N:7G-0029A-F, 7G-0030A-F, 7G-0031A-F, 7G-0032A-F.
8.The QEB75 meets EN55022 class A and class B only with external components connected before the input pin to the converter.
9.An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter capacitor Power Mate suggest: Nippon chemi-con KY series, 220μF/100V, ESR 48mΩ.
10.BASEPLATE GROUNDING:Base-plate should be grounded at one of the four screw bolts prior to operation.
11.The converter is provided by basic insulation.
Page 2 of 4 Issued Date:2008/05/21