INPUT SPECIFICATIONS
Parameter
Operating input voltage range
Start-up voltage
Shutdown voltage
Start up time
Input surge voltage
Input filter (1)
Remote ON/OFF
Constant resistive load
1 second, max.
Referred to –Vin pin
Conditions
24Vin(nom)
48Vin(nom)
110Vin(nom)
24Vin(nom)
48Vin(nom)
110Vin(nom)
24Vin(nom)
48Vin(nom)
110Vin(nom)
Power up
Remote ON/OFF
24Vin(nom)
48Vin(nom)
110Vin(nom)
Negative logic DC-DC ON
(Standard)
DC-DC OFF
Positive logic DC-DC ON
(Option)
DC-DC OFF
Input current of Ctrl pin
Remote off input current
Min. Typ. Max.
8.5
24
36
16.5
48
75
40
110
160
9
18
43
7.3
8.1
15.5
16.3
33.0
36.0
75
100
75
100
50
100
185
Pi type
Short or 0 ~ 1.2VDC
Open or 3 ~ 12 VDC
Open or 3 ~ 12 VDC
Short or 0 ~ 1.2VDC
-0.5
1
3
Unit
VDC
VDC
VDC
ms
VDC
mA
mA
OUTPUT SPECIFICATIONS
Parameter
Conditions
Voltage accuracy
Line regulation
Low Line to High Line at Full Load
Load regulation
No Load to Full Load
3.3 & 5Vout
Others
Voltage adjustability
Maximum output deviation is inclusive of remote sense
Remote sense
% of Vout(nom). If remote sense is not being used, sense pins should
connect to the output pins with the same polarity.
Ripple and noise
Measured by 20MHz bandwidth
With a 22µF/25V X7R MLCC
3.3Vout, 5Vout
With a 22µF/25V X7R MLCC
12Vout, 15Vout
With a 4.7µF/50V X7R MLCC
24Vout, 30Vout
With a 2.2µF/100V X7R MLCC
48Vout
Temperature coefficient
Transient response recovery time 25% load step change
Over voltage protection
% of Vout(nom); Hiccup mode
Over load protection
% of Iout rated; Hiccup mode
Short circuit protection
Min.
-1.0
-0.1
-0.2
-0.1
-20
Typ.
Max.
+1.0
+0.1
+0.2
+0.1
+10
10
Unit
%
%
%
%
%
75
100
mVp-p
200
300
-0.02
+0.02 %/
250
µs
115
130
%
110
140
%
Continuous, automatics recovery
GENERAL SPECIFICATIONS
Parameter
Conditions
Isolation voltage
1 minute (Basic insulation)
Input to Output
Input (Output) to Base-Plate
Isolation resistance
500VDC
Isolation capacitance
Switching frequency
Safety meets
Case material
Potting material
Weight
MTBF
MIL-HDBK-217F, Full load
Min. Typ. Max. Unit
2250
2250
VDC
1
GΩ
1500
pF
270
300
330
kHz
UL60950-1
EN60950-1
IEC60950-1
EN50155
Aluminum base-plate with plastic case
Silicone (UL94 V-0)
64g (2.26oz)
3.684 x 105 hrs