English
Language : 

FEC40-12S1P5 Datasheet, PDF (1/4 Pages) Power Mate Technology Co., LTD – 40 WATTS MAXIMUM OUTPUT POWER
APPLICATIONS
Wireless Network
Telecom/Datacom
Industry Control System
Measurement Equipment
Semiconductor Equipment
FEATURES
• 40 WATTS MAXIMUM OUTPUT POWER
• OUTPUT CURRENT UP TO 8A
• STANDARD 2.0 X 2.0 X 0.4 INCH PACKAGE
• HIGH EFFICIENCY UP TO 90%
• 2:1 WIDE INPUT VOLTAGE RANGE
• SIX-SIDED CONTINUOUS SHIELD
• FIXED SWITCHING FREQUENCY
• OFFER SINGLE, DUAL, DUAL POSITIVE
(TOTAL OUTPUT CURRENT 8A) AND TRIPLE OUTPUT
• CE MARK MEETS 2006/95/EC, 93/68/EEC AND 2004/108/EC
• UL60950-1, EN60950-1 AND IEC60950-1 LICENSED
• ISO9001 CERTIFIED MANUFACTURING FACILITIES
• COMPLIANT TO RoHS EU DIRECTIVE 2002/95/EC
DESCRIPTION
The FEC40 series offer 40 watts of output power from a 2 x 2 x 0.4 inch
package. The FEC40 series with 2:1 wide input voltage of
9-18VDC,18-36VDC and 36-75VDC and features 1600VDC of isolation,
short-circuit and over-voltage protection.
T E C H N I C A L S P E C I F I C A T I O N All specifications are typical at nominal input, full load and 25ºC otherwise noted
OUTPUT SPECIFICATIONS
Output power
40 Watts, max.
Voltage accuracy FL and nominal Vin
Single / Dual
Triple Main
Auxiliary
± 1%
± 1%
± 5%
Minimum load (Note 6)
See Table
Voltage adjustability (Note 7)
Single and Dual output only
(not including Dual Positive and triple)
± 10%
Single/Dual
± 0.5%
Line regulation LL to HL at Full Load Triple(main)
± 1%
Triple(auxiliary)
± 5%
Single
± 0.5%
Load regulation
(Note 8)
Min. Load to Full Load
Dual
Triple
Main
± 1%
± 2%
Auxiliary
± 5%
Load cross regulation
Triple(main)
± 1%
(Note 9)
Dual/Triple(auxiliary)
± 5%
Ripple and noise
(Note 10)
20MHz bandwidth
(Measured with a 0.1μF/50V MLCC)
See table
Temperature coefficient
±0.02% / ºC, max.
Transient response recovery time 25% load step change
250μS
1.5V output
1.8V output
Over voltage protection
Zener diode clamp
2.5V output
3.3V output
5V output
12V output
15V output
3.9VDC
3.9VDC
3.9VDC
3.9VDC
6.2VDC
15VDC
18VDC
Over load protection % of FL at nominal input
150%, max.
Short circuit protection
Hiccup, automatics recovery
GENERAL SPECIFICATIONS
Efficiency
See table
Isolation voltage
Isolation resistance
Input to Output
Input(Output) to Case
1600VDC, min.
1600VDC, min.
109ohms, min.
Isolation capacitance
1000pF, max.
Switching frequency (Note 11)
300KHz, typ.
Approvals and standard
IEC60950-1, UL60950-1, EN60950-1
Case material
Nickel-coated copper
Base material
FR4 PCB
Potting material
Epoxy (UL94-V0)
Dimensions
2.00 X 2.00 X 0.40 Inch
(50.8 X 50.8 X 10.2 mm)
Weight
MTBF (Note 1)
BELLCORE TR-NWT-000332
MIL-HDBK-217F
60g (2.11oz)
1.398 x 106 hrs
3.585 x 105 hrs
INPUT SPECIFICATIONS
Input voltage range
12V nominal inpu
24V nominal input
48V nominal input
9 – 18VDC
18 – 36VDC
36 – 75VDC
Input filter
L-C type
Input surge voltage
100mS max
12V input
24V input
48V input
36VDC
50VDC
100VDC
Input reflected ripple current Nominal Vin and full load
40mAp-p
Start up time
Nominal Vin and
constant resistive load
12V input
Start-up voltage
24V input
48V input
12V input
Shutdown voltage
24V input
48V input
Remote ON/OFF (Note 12)
(Positive logic)
DC-DC ON
DC-DC OFF
Powe up
Remote ON/OFF
25mS, typ.
25mS, typ.
9VDC
17.8VDC
36VDC
8VDC
16VDC
34VDC
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
Input current of remote control pin Nominal Vin
-0.5mA~+0.5mA
Remote off input current
Nominal Vin
2.5mA
ENVIRONMENTAL SPECIFICATIONS
Operating ambient temperature
-40ºC ~ +85ºC (with derating)
Maximum case temperature
+100ºC
Storage temperature range
Over temperature protection
Thermal impedance
(Note 13)
Thermal shock
Nature convection
Heat-sink with 20LFM
Heat-sink with 500LFM
-55ºC ~ +105ºC
115ºC, typ
9.2ºC/Watt
7.6ºC/Watt
2.8ºC/Watt
MIL-STD-810F
Vibration
MIL-STD-810F
Relative humidity
EMC CHARACTERISTICS
EM I (Note 14)
EN55022
ESD
EN61000-4-2
Radiated immunity EN61000-4-3
Fast transient (Note 15) EN61000-4-4
5% to 95% RH
Air ± 8KV
Contact ± 6KV
10 V/m
± 2KV
Class A
Perf. Criteria B
Perf. Criteria A
Perf. Criteria B
Surge (Note 15)
EN61000-4-5
± 1KV Perf. Criteria B
Conducted immunity EN61000-4-6
10 Vr.m.s Perf. Criteria A
Page 1 of 4 Issued Date:2008/06/12