PL520 Datasheet, PDF (7/9 Pages) OSRAM GmbH – Green Laser Diode in TO38 ICut Package
Version 1.0
PL 520
Important notes of operation for laser diode
a) Electrical operation
OSRAMs laser diodes are designed for maximum
performance and reliability. Operating the laser diode
above the maximum rating even for very short periods of
time can damage the laser diode or reduce its lifetime.
The laser diode must be operated with a suitable power
supply with minimized electrical noise.
The laser diode is very sensitive to electrostatic
discharge (ESD). Proper precautions must be taken.

b) Mounting instructions
In order to maintain the lifetime of the laser diode proper
heat management is essential. Due to the design of the
laser diode heat is dissipated only through the base
plate of the diode‘s body. A proper heat conducting
interconnection between the diodes base plate and the
heat sink must be maintained.
Wichtige Hinweise zum Betrieb der
Laserdiode
a) Elektrischer Betrieb
OSRAMs Laserdioden sind mit dem Ziel höchster
Leistung und Zuverlässigkeit gefertigt. Der Betrieb der
Laserdiode oberhalb der im Datenblatt angegebenen
Maximalwerte kann jedoch die Leistung und die
Zuverlässigkeit erheblich beeinträchtigen. Daher sollte
die Laserdiode auch mit einer möglichst rauscharmen
Stromversorgung betrieben werden.
Die Laserdiode ist sehr empfindlich gegenüber
elektrostatischen Entladungen (ESD). Entsprechende
Vorsichtsmaßnahmen sind zu treffen.
b) Verarbeitungshinweise 
Ein geeignetes Wärmemanagement ist
ausschlaggebend für eine lange Lebensdauer der
Laserdiode. Auf Grund des Designs wird die in der
Diode erzeugte Wärme haupsächlich über die
Grundplatte des Gehäuses abgeführt. Es muss
sichergestellt sein, dass eine ausreichend gut
wärmeleitende Verbindung zwischen der
Diodengrundplatte und dem Kühlkörper besteht.
28.05.2015
7