English
Language : 

805-RF315.0M-A_14 Datasheet, PDF (3/4 Pages) Oscilent Corporation – Remote Control, RF SAW Filter
January 2010 Rev A
Maximum Ratings
Parameters Description
Operating Temperature Range
Storage Temperature Range
Maximum DC Voltage
Maximum Input Power
Source Impedance (single ended)(1)
Load Impedance (single ended)(1)
Notes: With Matching Network
Oscilent Part Number
805-RF315.0M-A
Remote Control, RF SAW Filter
Unit
°C
°C
V
dBm
Ω
Ω
Minimum
-40
-40
-
-
-
-
Typical
-
-
-
-
50
50
Maximum
+105
+85
10
0
-
-
Electrical Specification
Parameters Description
Center Frequency (Fo)
Minimum Insertion Loss in 314.82 ~ 315.22 MHz, ILmin
Passband(relative to IL min)
314.77 ~ 315.2 MHz
314.71 ~ 315.26 MHz
3dB Passband Width(relative to IL min)
Stop Band Attenuation:
10 ~ 270.0 MHz
270.0 ~ 309.0 MHz
309.0 ~ 313.94 MHz
316.0 ~ 335.0 MHz
335.0 ~ 400.0 MHz
400.0 ~ 1000.0 MHz
Unit
MHz
dB
Minimum
-
-
Typical
315.0
2.0
Maximum
-
4.0
dB
-
dB
-
MHz
0.8
1.5
3.0
2.0
6.0
0.92
-
dB
45
55
-
dB
30
35
-
dB
15
20
-
dB
10
15
-
dB
35
45
-
dB
45
55
-
Product Specification
P. 2
www.oscilent.com