Maximum Ratings
Parameters Description
Operating Temperature Range
Storage Temperature Range
Maximum DC Voltage
Maximum Input Power
Source Impedance (single ended)(1)
Load Impedance (single ended)(1)
Notes: No Matching Network
Electrical Specification
Parameters Description
Center Frequency (Fo)
Insertion Loss in 465.2 ~470.0 MHz
Attenuation:
0.3 ~ 455.2 MHz
455.2 ~ 460.0 MHz
490.0 ~ 700.0 MHz
700.0 ~ 1200 MHz
1200 ~ 2000 MHz
VSWR in 465.2 ~ 470.0 MHz
Oscilent Part Number
803-RF467.6M-A
CDMA 450 G-Band, RF/Rx SAW Filter
Unit
°C
°C
V
dBm
Ω
Ω
Minimum
-30
-40
-
-
-
-
Typical
-
-
-
-
50
50
Maximum
+80
+85
0
27
-
-
Unit
MHz
dB
Minimum
-
-
Typical
467.6
2.8
Maximum
-
3.5
dB
40
50
-
dB
35
49
-
dB
40
50
-
dB
30
42
-
dB
20
35
-
-
-
1.8
2.0
Product Specification
P. 2