English
Language : 

802-RF412.75M-B Datasheet, PDF (3/5 Pages) Oscilent Corporation – CDMA 450 L-Band, RF-Tx SAW Filter
January 2010 Rev A
Maximum Ratings
Parameters Description
Operating Temperature Range
Storage Temperature Range
Maximum DC Voltage
Maximum Input Power
Source Impedance (single ended)(1)
Load Impedance (single ended)(1)
(1) No Matching Network
Electrical Specification
Parameters Description
Center Frequency (Fo)
Insertion Loss in 410.5 ~415.0 MHz
Stop Band Attenuation:
0.3 ~ 400.0 MHz
420.5 ~ 425.0 MHz
425.0 ~ 1700.0 MHz
1700.0 ~ 2000.0 MHz
VSWR in 410.5 ~ 415.0 MHz
Oscilent Part Number
802-RF412.75M-B
CDMA 450 L-Band, RF/Tx SAW Filter
Unit
°C
°C
V
dBm
Ω
Ω
Minimum
-30
-40
-
-
-
-
Typical
-
-
-
-
50
50
Maximum
+80
+85
0
30
-
-
Unit
MHz
dB
Minimum
-
-
Typical
412.75
2.5
Maximum
-
2.8
dB
23
26
-
dB
30
48
-
dB
20
27
-
dB
15
22
-
-
-
1.3
2.0
Product Specification
P. 2
www.oscilent.com