5. Test
No change on display and in operation under the following test condition.
Conditions:
Unless otherwise specified, tests will be conducted under the following condition.
Temperature: 20±5°C
Humidity : 65±5%RH
tests will be not conducted under functioning state.
No.
Parameter
1 High Temperature Operating
2 Low Temperature Operating
3 High Temperature Storage
4 Low Temperature Storage
5 Damp Proof Test
6 Vibration Test
7 Shock
8 Shock Test
Conditions
Notes
60°C, 96hrs (operation state)
0°C, 96hrs (operation state)
1
70°C, 96hrs
2
-25°C, 96hrs
1,2
40°C,90~95%RH, 96hrs
1,2
Frequency:10-57Hz/Vibration width(one side):0.075mm 3
:58-500Hz/Gravity:9.8m/s2
Sweep time:11minutes
Test period:3hrs for each direction of X,Y,Z
Shock level:490m/s2
Waveform:half sinusoidal wave, 11ms
Number of shocks :
One shock input in each direction of three mutually
perpendicular axis for a total of six shock inputs
To be measured after dropping from 60cm high on
the concrete surface in packing state.
E
B
Dropping method corner dropping
F
A corner : once
GD C
A
60cm
Concrete Surface
Edge dropping
B,C,D edge : once
Face dropping
E,F,G face : once
Note 1: No dew condensation to be observed.
Note 2: The function test shall be conducted after 4 hours storage at the normal
Temperature and humidity after removed from the test chamber.
Note 3: Vibration test will be conducted to the product itself without putting it in a container.
T-51750GD065J-FW-AA (AA) No. 2003-0199
OPTREX CORPORATION