Plastic Infrared Emitting Diode
OP290 Series
Electrical Characteristics (TA = 25°C unless otherwise noted)
SYMBOL
PARAMETER
MIN TYP MAX UNITS
TEST CONDITIONS
Input Diode
Apertured Radiant Incidence
OP290A
OP290B
OP290C
OP291A
OP291B
OP291C
OP292A
OP292B
OP292C
OP293A
OP293B
OP293C
OP294
EE
(2)
(APT)
OP295A
OP295B
OP295C
OP296A
OP296B
OP296C
OP297A
OP297B
OP297C
OP298A
OP298B
OP298C
210 -
-
180 - 300
150 -
-
IF = 1.50 A(1)(2)
Measured into a 0.250” [6.35mm] aperture
0.2” (5.08 mm) from the tip of the lens.
16
-
13
-
26
10
-
IF = 100 mA(1)(2)
Measured into a 0.250” [6.35mm] aperture
0.2” (5.08 mm) from the tip of the lens.
2.7 -
2.2 3.6 4.4
1.7 -
IF = 20 mA(1)(2)
Measured into a 0.250” [6.35mm] aperture
0.2” (5.08 mm) from the tip of the lens.
16
-
13 22 26
10
-
IF = 100 mA(1)(2)
Measured into a 0.250” [6.35mm] aperture
0.2” (5.08 mm) from the tip of the lens.
0.50 - 1.50
IF = 5 mA(1)(2)
Measured into a 0.250” [6.35mm] aperture
1.129” (28.7mm) from the tip of the lens.
44
-
IF = 1.50 A(1)(2)
33
-
77 mW/cm2 Measured into a 0.250” [6.35mm] aperture
22
-
1.129” (28.7 mm) from the tip of the lens.
3.6 -
2.6 - 6.6
1.6 -
IF = 100 mA(1)(2)
Measured into a 0.250” [6.35mm] aperture
1.129” (28.7 mm) from the tip of the lens.
0.7 -
0.5 1.0 1.3
0.3 -
IF = 20 mA(1)(2)
Measured into a 0.250” [6.35mm] aperture
1.129” (28.7 mm) from the tip of the lens.
3.0 -
2.4 - 4.8
1.8 -
IF = 100 mA(1)(2)
Measured into a 0.250” [6.35mm] aperture
0.2” (5.08 mm) from the tip of the lens.
OP298AA
OP298AB
OP298AC
OP298AD
OP299
3.5 -
-
3.5 - 8.5
6.5 - 11.5
8.5 -
-
0.15 - 0.45
IF = 100 mA(1)(2)
Measured into a 0.250” [6.35mm] aperture
1.129” (28.7 mm) from the tip of the lens.
IF = 100 mA(1)(2)
Measured into a 0.250” [6.35mm] aperture
1.129” (28.7 mm) from the tip of the lens.
Notes:
1. Measurement is taken at the end of a single 100 µs pulse. Heating due to increased pulse rate or pulse width will cause a decrease
in reading.
2. Measurement of the average apertured radiant energy incident upon a sensing area 0.250” (6.35 mm) in diameter perpendicular to
and centered on the mechanical axis of the lens and the specified distance from the end of the device. On all models in this series,
EE(APT) is not necessarily uniform within the measured area.
3. Measurement is taken at the end of a single 10 ms pulse. Heating due to increased pulse rate or pulse width will cause a decrease in
reading.
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Issue A 05/07
Page 4 of 8