English
Language : 

OP270 Datasheet, PDF (2/3 Pages) Analog Devices – Dual Very Low Noise Precision Operational Amplifier
SMD Infrared LED
OP270 Series
Absolute Maximum Ratings (TA = 25o C unless otherwise noted)
PARAMETER
SYMBOL
Continuous Forward Current
IF
Power Dissipation
Pd
Reverse Voltage
IR
Peak Forward Current (1μs pulse width, 300 pps)
IFP
Lead Soldering Temperature
(1.6mm to epoxy for 5 sec.)
TSOL
Operating Temperature Range
Storage Temperature Range
Notes:
1. Solder time less than 5 seconds at temperature extreme.
2. De-rate linearly at 2.17 mW/° C above 25° C.
TOPR
TSTG
MAXIMUM
50
130
2
1
UNITS
mA
mW
V
A
260º
C
-40ºC to +85ºC
-40ºC to +100ºC
Electrical Characteristics (TA = 25°C unless otherwise noted)
SYMBOL
PARAMETER
MIN TYP MAX UNITS
CONDITIONS
Ee(APT)
Apertured Radiant Incidence
1.5
VF
Forward Voltage
mW/cm2 IF = 20mA(3)
1.5
V
IF = 20mA
IR
Reverse Current
100
µA VR = 2.0V
λP
Peak Emission Wavelength
890
nm IF = 10mA
ΘHP
Emission Angle at Half Power Points
25
Deg. IF = 20mA
tr, tf
Rise and Fall Time
500
ns
IF(PEAK) = 100mA, PW = 10µs, 10% D.C.
3. Ee(APT) is a measurement of the apertured radiant incidence upon a sensing area 0.081” (2.06mm) in diameter, perpendicular to and cen-
tered on the mechanical axis of the lens, and 0.590” (14.99mm) from the measurement surface. Ee(APT) is not necessarily uniform within
the measured area.
Relative Radiant Intensity vs.
Forward Current vs. Temperature
350%
300%
Normalized at IF = 20mA,
TA = 20°C. Temperatures
stepped in 20°C Increments
-40°C
Forward Voltage vs. Forward
Current vs. Temperature
1.5
Temperatures stepped
in 20 °C Increments
-40°C
1.4
250%
200%
1.3
150%
100%
50%
1.2
100°C
1.1
100°C
0
10
20
30
40
50
1.0
0
Forward Current (mA)
OPTEK Technology Inc.— 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (800) 341-4747 FAX: (972) 323– 2396 sensors@optekinc.com www.optekinc.com
10
20
30
40
50
Forward Current (mA)
Issue A.3 07/08