English
Language : 

OP140A Datasheet, PDF (1/2 Pages) OPTEK Technologies – GaAs Plastic Infrared Emitting Diodes
Product Bulletin OP140A
May 1996
GaAs Plastic Infrared Emitting Diodes
Types OP140A, OP140B, OP140C, OP140D
Features
• Wide irradiance pattern
• Selected to specific on-line intensity
ranges
• Low cost, miniature plastic side-
looking package
• Mechanically and spectrally matched
to the OP550 series of
phototransistors and the OP560 series
of photodarlingtons
Description
The OP140 series devices are 935nm
high intensity gallium arsenide infrared
emitting diodes molded in IR
transmissive plastic side-looking
packages. The side looking packages
are for use in PC board mounted slotted
switches or as an easy mount PC board
interrupter.
Absolute Maximum Ratings (TA = 25o C unless otherwise noted)
Reverse Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.0 V
Continuous Forward Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA
Peak Forward Current (1 µs pulse width, 300 pps) . . . . . . . . . . . . . . . . . . . . . . . 3.0 A
Storage and Operating Temperature Range . . . . . . . . . . . . . . . . . . -40o C to +100o C
Lead Soldering Temperature [1/16 inch (1.6 mm) from case for 5 sec. with soldering
iron] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260o C(1)
Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 mW(2)
Notes:
(1) RMA flux is recommended. Duration can be extended to 10 sec. max. when flow soldering.
A max. of 20 grams force may be applied to the leads when soldering.
(2) Derate linearly 1.33 mW/o C above 25o C.
(3) Ee(APT) is a measurement of the average apertured radiant incidence upon a sensing area
0.180" (4.57 mm) in diameter perpendicular to and centered on the mechanical axis of the
lens and 0.653" (16.6 mm) from the lens tip. Ee(APT) is not necessarily uniform within the
measured area.
Replaces
OP140SL series
2-10