English
Language : 

TXC3XGHI2X Datasheet, PDF (1/7 Pages) OPLINK Communications Inc. – Transceivers with Digital Diagnostics
Multi-rate 10-Gigabit CWDM 40km XFP
Transceivers with Digital Diagnostics
TXC3XGHI2x
Pb
Product Description
The TXC3XGHI2x CWDM XFP multi-rate fiber optic transceivers with digital
diagnostics monitoring functionality provide a quick and reliable interface
for 10Gbps CWDM applications. The diagnostic functions, alarm and warning
features as described in the XFP Multi-Source Agreement (MSA) are provided
via standard I2C serial interface. The transceivers are designed to support
the XFP Multi-Source Agreement, and multiple data rates from 9.95Gb/s to
11.09Gb/s for OC-192, 10G Ethernet, 10G Fiber Channel and FEC applications.
Each transceiver utilizes an electro-absorption modulated laser with an
operating wavelength selectable to ITU-T standards covering CWDM grid
wavelengths. They satisfy Class I Laser Safety requirements in accordance with
the U.S. FDA/CDRH and international IEC-60825 standards.
The transceivers connect to standard 30-pad XFP connectors for hot plug
capability. This allows the system designer to make configuration changes or
maintenance by simply plugging in different types of transceivers without
removing the power supply from the host system.
The transmitter and receiver DATA interfaces are AC coupled Current Mode
Logic (CML). LV-TTL Transmitter Disable control input and Loss of Signal output
interfaces are also provided.
The transceivers operate from +3.3V and +5.0V power supplies over a
operating case temperature range of -5°C to +70°C (Commercial), -5°C to +85°C
(Extended), or -40°C to +85°C (Industrial). The housing is made of metal for EMI
immunity.
Features
 Lead Free Design & Fully RoHS Compliant
 Compliant with XFP MSA
 Compliant with OC-192/STM-64
 Compliant with ITU-T G.709
 Support 10G Ethernet Applications
 Support 10G Fiber Channel Applications
 Compatible with ITU-T G.695
 Digital Diagnostics Monitoring
 Temperature-stabilized EML Transmitter
 Low Power Consumption
 Wide Case Operating Temperature Range
 Distance up to 40km with G.652 Fiber
Absolute Maximum Ratings
Parameter
Storage Temperature Range
Case Operating Temperature 1
Commercial
Extended
Industrial
Supply Voltage
Operating Relative Humidity 2
Input Voltage
1 Case temperature is measured on top side of XFP module.
2 Non condensing
Symbol
TST
TOP
VCC 3
VCC 5
RH
VIN
Minimum
- 40
-5
-5
- 40
- 0.2
- 0.2
0
0
Maximum
+ 85
+ 70
+ 85
+ 85
+ 3.6
+ 6.0
85
V CC
Units
°C
°C
V
%
V
S0369. Rev.02. (web) 2014-02-10