English
Language : 

NCL30086 Datasheet, PDF (7/28 Pages) ON Semiconductor – Controller for LED Lighting
NCL30086
Table 4. ELECTRICAL CHARACTERISTICS (Unless otherwise noted: For typical values TJ = 25°C, VCC = 12 V, VZCD = 0 V,
VCS = 0 V, VSD = 1.5 V) For min/max values TJ = −40°C to +125°C, VCC = 12 V)
Description
Test Condition
Symbol
Min Typ Max Unit
CONSTANT CURRENT AND POWER FACTOR CONTROL
Error amplifier current capability
VREFX = VREF (no dimming)
IEA
VREFX = 25%* VREF
±60
mA
±240
COMP Pin Start−up Current Source
LINE FEED FORWARD
COMP pin grounded
IEA_STUP
140
mA
VVS to ICS(offset) conversion ratio
Line feed−forward current on CS pin
Offset current maximum value
VALLEY LOCKOUT SECTION
DRV high, VVS = 2 V
KLFF
18
20
22
mS
IFF
35
40
45
mA
Ioffset(MAX)
80 100 120
mA
Threshold for high− line range (HL) detection
Threshold for low−line range (LL) detection
Blanking time for line range detection
FREQUENCY FOLDBACK
VVS rising
VVS falling
VHL
VLL
tHL(blank)
2.28 2.40 2.52
V
2.18 2.30 2.42
V
15
25
35
ms
Minimum additional dead time in frequency fold-
back mode
tFF1LL
1.4 2.0 2.6
ms
Additional dead time
Additional dead time
FAULT PROTECTION
VREFX = 5% VREF
VREFX = 0% VREF
tFF2HL
tFF3HL
−
40
−
ms
90
−
ms
Thermal Shutdown (Note 6)
Thermal Shutdown Hysteresis
Threshold voltage for output short circuit or aux.
winding short circuit detection
FSW = 65 kHz
TSHDN
130 150 170
°C
TSHDN(HYS)
−
50
–
°C
VZCD(short)
0.8
1.0
1.2
V
Short circuit detection Timer
Auto−recovery timer duration
SD pin Clamp series resistor
Clamped voltage
SD pin detection level for OVP
Delay before OVP or OTP confirmation
Reference current for direct connection of an
NTC (Note 8)
VZCD < VZCD(short)
SD pin open
VSD rising
tOVLD
70
90 110
ms
trecovery
3
4
5
s
RSD(clamp)
1.6
kW
VSD(clamp)
1.13 1.35 1.57
V
VOVP
2.35 2.50 2.65
V
TSD(delay)
22.5 30.0 37.5
ms
IOTP(REF)
80
85
90
mA
Fault detection level for OTP (Note 7)
SD pin level for operation recovery after an OTP
detection
VSD falling
VSD rising
VOTP(off)
0.47 0.50 0.53
V
VOTP(on)
0.66 0.70 0.74
V
OTP blanking time when circuit starts operating
(Note 8)
tOTP(start)
250
370
ms
SD pin voltage where thermal fold−back starts
(VREF is decreased)
VTF(start)
0.94 1.00 1.06
V
SD pin voltage at which thermal fold−back stops
(VREF is clamped to VREF50)
VTF(stop)
0.64 0.69 0.74
V
VTF(start) over IOTP(REF) ratio (Note 7)
TJ = +25°C to +125°C
RTF(start)
10.8 11.7 12.6
kW
6. Guaranteed by Design
7. A NTC is generally placed between the SD and GND pins. Parameters RTF(start), RTF(stop), ROTP(off) and ROTP(on) give the resistance the
NTC must exhibit to respectively, enter thermal foldback, stop thermal foldback, trigger the OTP limit and allow the circuit recovery after
an OTP situation.
8. At startup, when VCC reaches VCC(on), the controller blanks OTP for more than 250 ms to avoid detecting an OTP fault by allowing the
SD pin voltage to reach its nominal value if a filtering capacitor is connected to the SD pin.
www.onsemi.com